Metraipolis › archive › dc_46af7acfda90

Modeling and Parametrization of Large-scale Hydrogen Electrolyzers for Transient and Frequency Stability Analysis — arXiv:2610.39819

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.39819
License (as archived)
CC0-1.0
Archived
2026-11-01T03:00:45.208Z
SHA-256 of the archived text
b7ae78faae4131557d4d91739d3f00db31db500a9765475d7f4a74a761b62233
Stable URL of this page
https://metraipolis.com/documento/dc_46af7acfda90

How to cite

Modeling and Parametrization of Large-scale Hydrogen Electrolyzers for Transient and Frequency Stability Analysis — arXiv:2610.39819 — arXiv (en), https://arxiv.org/abs/2610.39819 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_46af7acfda90 (Metraipolis archive dc_46af7acfda90, sha256 b7ae78faae4131557d4d91739d3f00db31db500a9765475d7f4a74a761b62233)
BibTeX
@misc{dc46af7acfda90,
  title = {Modeling and Parametrization of Large-scale Hydrogen Electrolyzers for Transient and Frequency Stability Analysis — arXiv:2610.39819},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.39819},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_46af7acfda90; sha256 b7ae78faae4131557d4d91739d3f00db31db500a9765475d7f4a74a761b62233},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39819. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Hydrogen Electrolyzers (HEs), particularly Proton Exchange Membrane (PEM)-based systems, are flexible loads capable of providing grid ancillary services and enhancing the stability of renewable-dominated power systems due to their fast electrical response. However, the literature often lacks clear guidance on the structure, modeling, and parametrization of large-scale HEs for transient and frequency stability analyses. This paper presents a detailed configuration for utility-scale HE plants, using the stack as the fundamental unit, supported by a realistic parametrization based on commercial components. Furthermore, this work extends the Generalized ESS Model (GEM), a linearized state-space model previously utilized with other converter-interfaced energy storage systems, to PEM HEs for the first time. To facilitate plant scalability, a robust method for scaling GEM matrices across different capacities is proposed. Finally, a measurement-based methodology is developed to estimate the GEM parameters and subsequently extract the equivalent electrical circuit parameters. Comprehensive simulations on the WSCC system under various disturbances validate the accuracy of the derived GEM, the effectiveness of the scaling approach, and the robustness of the parameter identification methodology.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2610.39819 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:25:30.749Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).