Metraipolis › archive › dc_45ea34a05215

Rotate Disks to Reach Farther: Design and Modeling of a Novel Reconfigurable Tendon Driven Manipulator — arXiv:2608.15946

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.15946
License (as archived)
CC0-1.0
Archived
2026-10-18T23:05:56.504Z
SHA-256 of the archived text
23ac05b68c36319ced8afb6a3228e7f63da8f25ee04e7fb2706b8293b3d4dd31
Stable URL of this page
https://metraipolis.com/documento/dc_45ea34a05215

How to cite

Rotate Disks to Reach Farther: Design and Modeling of a Novel Reconfigurable Tendon Driven Manipulator — arXiv:2608.15946 — arXiv (en), https://arxiv.org/abs/2608.15946 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_45ea34a05215 (Metraipolis archive dc_45ea34a05215, sha256 23ac05b68c36319ced8afb6a3228e7f63da8f25ee04e7fb2706b8293b3d4dd31)
BibTeX
@misc{dc45ea34a05215,
  title = {Rotate Disks to Reach Farther: Design and Modeling of a Novel Reconfigurable Tendon Driven Manipulator — arXiv:2608.15946},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.15946},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_45ea34a05215; sha256 23ac05b68c36319ced8afb6a3228e7f63da8f25ee04e7fb2706b8293b3d4dd31},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.15946. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Rerouting the tendon path in tendon driven continuum manipulators (TDCMs) enables a broad range of deformation modes. This work presents a Reconfigurable TDCM design which allows independent rotation of intermediate spacer disks, thereby locally rerouting the tendon and achieving non-trivial backbone spatial deformations. Two such designs, (a) Manual Disk Locked (MDL) and (b) Continuous Disk Rotor (CDR) manipulators are presented to achieve disk rotations before and during operation, respectively. A predictive static model based on the piecewise constant strain (PCS) assumption is developed within a potential energy minimization framework, incorporating (a) disk rotations, (b) discrete tendon paths between disk segments, (c) rigid thickness of spacer disks, and (d) elasticity of the tendons. The model is validated against experimental results, demonstrating an average tip error of $1.2\%$ of the manipulator's total length for parallel tendon routing and around $3\%$ for the case when multiple disks are rotated. The computation time is an order of magnitude lower than the state of the art Cosserat rod solver.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-18 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2608.15946 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T23:01:50.370Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-08-18?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).