Metraipolis › archive › dc_457dc7d07615

ARCGym: Benchmarking Deep Reinforcement Learning in Autonomous Robotic Colonoscopy — arXiv:2609.22803

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.22803
License (as archived)
CC0-1.0
Archived
2026-10-09T22:23:35.349Z
SHA-256 of the archived text
599bd623784ae6b01cb6be73c37d778d9aa72c22867ca81baa41bca09bd64a5c
Stable URL of this page
https://metraipolis.com/documento/dc_457dc7d07615

How to cite

ARCGym: Benchmarking Deep Reinforcement Learning in Autonomous Robotic Colonoscopy — arXiv:2609.22803 — arXiv (en), https://arxiv.org/abs/2609.22803 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_457dc7d07615 (Metraipolis archive dc_457dc7d07615, sha256 599bd623784ae6b01cb6be73c37d778d9aa72c22867ca81baa41bca09bd64a5c)
BibTeX
@misc{dc457dc7d07615,
  title = {ARCGym: Benchmarking Deep Reinforcement Learning in Autonomous Robotic Colonoscopy — arXiv:2609.22803},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.22803},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_457dc7d07615; sha256 599bd623784ae6b01cb6be73c37d778d9aa72c22867ca81baa41bca09bd64a5c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.22803. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Simulations for learning-based autonomous colonoscopic navigation focus mainly on fully actuated capsule robots, failing to capture the contact-rich navigation of long and flexible clinical colonoscopes. We present the Autonomous Robotic Colonoscopy Gym (ARCGym), an open-source reinforcement learning environment and benchmark for image-based navigation in clinically derived deformable colon anatomies. ARCGym supports multiple types of colonoscope robots, spanning capsule robots and flexible endoscopes, with this work focusing on flexible endoscopes including magnetic-driven tip actuation and clinically used proximally translational actuation. This work includes five CT-reconstructed colons representing typical clinical scenarios, a set of clinically meaningful navigation subtasks, and unified success metrics. We introduce a reward combining depth-based lumen alignment with a lumen-visibility score to improve learning under occlusions. Experiments across tasks, robots, and anatomies show that autonomous navigation remains challenging for both magnetic-driven and proximal-insertion flexible robots, with proximal-insertion actuation remaining an open problem.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-22 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2609.22803 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T21:59:59.478Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).