Metraipolis › archive › dc_43b52290e158

Attention-guided super-resolution of 4D flow MRI in carotid arteries — arXiv:2609.04891

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.04891
License (as archived)
CC0-1.0
Archived
2026-10-16T22:26:46.043Z
SHA-256 of the archived text
b53cb1320b8f179510a73c34794cd6f2431a19b8a605f3338933228fa37bf950
Stable URL of this page
https://metraipolis.com/documento/dc_43b52290e158

How to cite

Attention-guided super-resolution of 4D flow MRI in carotid arteries — arXiv:2609.04891 — arXiv (en), https://arxiv.org/abs/2609.04891 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_43b52290e158 (Metraipolis archive dc_43b52290e158, sha256 b53cb1320b8f179510a73c34794cd6f2431a19b8a605f3338933228fa37bf950)
BibTeX
@misc{dc43b52290e158,
  title = {Attention-guided super-resolution of 4D flow MRI in carotid arteries — arXiv:2609.04891},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.04891},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_43b52290e158; sha256 b53cb1320b8f179510a73c34794cd6f2431a19b8a605f3338933228fa37bf950},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.04891. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-07 in cs.AI).
Categorie arXiv: Medical Physics (physics.med-ph) ; Artificial Intelligence (cs.AI); Fluid Dynamics (physics.flu-dyn).
Pagina del lavoro: https://arxiv.org/abs/2609.04891 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).