Metraipolis › archive › dc_438f971c303d

Multi-Aperture PPG with MAPIS: Spatial Optical and Temporal Coherence Fields — arXiv:2609.33790

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.33790
License (as archived)
CC0-1.0
Archived
2026-10-07T23:55:07.755Z
SHA-256 of the archived text
fdd2a5cc1df390fe84d88cb913534b096044a90cdc444a683c84c099e0c4781b
Stable URL of this page
https://metraipolis.com/documento/dc_438f971c303d

How to cite

Multi-Aperture PPG with MAPIS: Spatial Optical and Temporal Coherence Fields — arXiv:2609.33790 — arXiv (en), https://arxiv.org/abs/2609.33790 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_438f971c303d (Metraipolis archive dc_438f971c303d, sha256 fdd2a5cc1df390fe84d88cb913534b096044a90cdc444a683c84c099e0c4781b)
BibTeX
@misc{dc438f971c303d,
  title = {Multi-Aperture PPG with MAPIS: Spatial Optical and Temporal Coherence Fields — arXiv:2609.33790},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.33790},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_438f971c303d; sha256 fdd2a5cc1df390fe84d88cb913534b096044a90cdc444a683c84c099e0c4781b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.33790. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Conventional reflectance photoplethysmography (PPG) typically reduces tissue optical responses to one or a few detector channels. Matrix Pinhole Image Sensing (MAPIS) instead simultaneously samples multiple aperture-dependent optical signals. We analyzed 44 recordings of 30 seconds each from a single MAPIS device to characterize the spatial relationships among DC intensity, pulsatile AC, perfusion index (PI), and temporal coherence across Red and infrared channels. AC increased sublinearly with DC at both wavelengths, resulting in higher PI toward lower-DC apertures, consistent with a first-order relative path-sensitivity interpretation. A second counterintuitive spatial trend was observed in temporal coherence: lower-DC and lower-AC apertures exhibited higher autocorrelation and greater cardiac-periodic spectral concentration. IR signals also showed consistently higher temporal coherence than corresponding Red signals. These observations demonstrate that multi-aperture PPG resolves reproducible spatial relationships among optical intensity, fractional pulsatile sensitivity, and waveform coherence that are largely averaged together in conventional single-channel PPG. The present study establishes within-device relationships and motivates controlled studies of the underlying photon-path mechanisms.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV).
Categorie arXiv: Optics (physics.optics) ; Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.33790 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T23:29:27.691Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).