Metraipolis › archive › dc_435997a57ab2

Anguinus Sculpturae: Compositional Synthesis of Peak-Enhancement Breast DCE-MRI Scans — arXiv:2609.33611

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.33611
License (as archived)
CC0-1.0
Archived
2026-10-07T23:51:42.942Z
SHA-256 of the archived text
20b32ac8f07b2bfa41a6e7edfd1269ca9d5e3bc40b02df85598046993a793baf
Stable URL of this page
https://metraipolis.com/documento/dc_435997a57ab2

How to cite

Anguinus Sculpturae: Compositional Synthesis of Peak-Enhancement Breast DCE-MRI Scans — arXiv:2609.33611 — arXiv (en), https://arxiv.org/abs/2609.33611 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_435997a57ab2 (Metraipolis archive dc_435997a57ab2, sha256 20b32ac8f07b2bfa41a6e7edfd1269ca9d5e3bc40b02df85598046993a793baf)
BibTeX
@misc{dc435997a57ab2,
  title = {Anguinus Sculpturae: Compositional Synthesis of Peak-Enhancement Breast DCE-MRI Scans — arXiv:2609.33611},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.33611},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_435997a57ab2; sha256 20b32ac8f07b2bfa41a6e7edfd1269ca9d5e3bc40b02df85598046993a793baf},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.33611. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Dynamic contrast-enhanced breast MRI (DCE-MRI) is rich in anatomical and perfusion information, but its reliance on gadolinium-based contrast agents raises safety concerns and adds cost. Virtual contrast enhancement, synthesizing post-contrast from pre-contrast images, is a promising alternative. We address the MAMA-SYNTH challenge task of predicting peak-enhancement breast MRI. Rather than adopting the full machinery of diffusion or flow matching, we observe that under a rectified, straight-line path the generative process collapses to a single difference prediction: the synthetic peak image is the pre-contrast image plus a predicted enhancement map, recovered in one forward pass. Around this we build Anguinus Sculpturae, a compositional pipeline in which nnU-Net segmentations of lesion, foreground and breast region guide two generators - one optimized for global fidelity, one for lesion structure through an asymmetric Tversky term routed via a frozen segmenter - composited region-wise with Gaussian-weighted blending. On the held-out Duke subset of MAMA-MIA our model achieves the best FRD and Dice among all evaluated variants, showing that single-step difference prediction with segmentation guidance suffices to recover both global fidelity and lesion structure. Code is available at this https URL .

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.33611 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T23:29:27.237Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).