Metraipolis › archive › dc_4317c483e2ad

Repeatability and reproducibility of a handheld quantitative G6PD diagnostic — Europe PMC PMID:35176015

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/35176015
DOI
10.1371/journal.pntd.0010174
License (as archived)
CC0-1.0
Archived
2026-10-31T09:28:14.753Z
SHA-256 of the archived text
1fce05eb68d1d5ae7fa3e4449526812833f295c3a81c8361ba90e16b9005c719
Stable URL of this page
https://metraipolis.com/documento/dc_4317c483e2ad

How to cite

Repeatability and reproducibility of a handheld quantitative G6PD diagnostic — Europe PMC PMID:35176015 — Europe PMC (en), https://europepmc.org/article/MED/35176015 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4317c483e2ad (Metraipolis archive dc_4317c483e2ad, sha256 1fce05eb68d1d5ae7fa3e4449526812833f295c3a81c8361ba90e16b9005c719)
BibTeX
@misc{dc4317c483e2ad,
  title = {Repeatability and reproducibility of a handheld quantitative G6PD diagnostic — Europe PMC PMID:35176015},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/35176015},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4317c483e2ad; sha256 1fce05eb68d1d5ae7fa3e4449526812833f295c3a81c8361ba90e16b9005c719},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/35176015. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: The introduction of novel short course treatment regimens for the radical cure of Plasmodium vivax requires reliable point-of-care diagnosis that can identify glucose-6-phosphate dehydrogenase (G6PD) deficient individuals. While deficient males can be identified using a qualitative diagnostic test, the genetic make-up of females requires a quantitative measurement. SD Biosensor (Republic of Korea) has developed a handheld quantitative G6PD diagnostic (STANDARD G6PD test), that has approximately 90% accuracy in field studies for identifying individuals with intermediate or severe deficiency. The device can only be considered for routine care if precision of the assay is high. Methods and findings: Commercial lyophilised controls (ACS Analytics, USA) with high, intermediate, and low G6PD activities were assessed 20 times on 10 Biosensor devices and compared to spectrophotometry (Pointe Scientific, USA). Each device was then dispatched to one of 10 different laboratories with a standard set of the controls. Each control was tested 40 times at each laboratory by a single user and compared to spectrophotometry results. When tested at one site, the mean coefficient of variation (CV) was 0.111, 0.172 and 0.260 for high, intermediate, and low controls across all devices respectively; combined G6PD Biosensor readings correlated well with spectrophotometry (rs = 0.859, p<0.001). When tested in different laboratories, correlation was lower (rs = 0.604, p<0.001) and G6PD activity determined by Biosensor for the low and intermediate controls overlapped. The use of lyophilised human blood samples rather than fresh blood may have affected these findings. Biosensor G6PD readings between sites did not differ significantly (p = 0.436), whereas spectrophotometry readings differed markedly between sites (p<0.001). Conclusions: Repeatability and inter-laboratory reproducibility of the Biosensor were good; though the device did not reliably discriminate between intermediate and low G6PD activities of the lyophilized specimens. Clinical studies are now required to assess the devices performance in practice.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PLoS neglected tropical diseases, 2022 (prima pubblicazione 2022-02-17).
Identificativi: PMID 35176015 · PMCID PMC8853557 · DOI 10.1371/journal.pntd.0010174.
Pagina: https://europepmc.org/article/MED/35176015 — https://doi.org/10.1371/journal.pntd.0010174. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-31T09:18:13.100Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.