Metraipolis › archive › dc_4303776a33e3
Radiometric Thermal Imaging Dataset of Laboratory Rats with Anatomical Segmentation Masks — arXiv:2608.03481
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.03481
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T13:28:57.511Z
- SHA-256 of the archived text
8b9c3bd39a050a916435c4c9d0bb12647fa0d72a287ff8c41c596adc27908640- Stable URL of this page
https://metraipolis.com/documento/dc_4303776a33e3
How to cite
Radiometric Thermal Imaging Dataset of Laboratory Rats with Anatomical Segmentation Masks — arXiv:2608.03481 — arXiv (en), https://arxiv.org/abs/2608.03481 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4303776a33e3 (Metraipolis archive dc_4303776a33e3, sha256 8b9c3bd39a050a916435c4c9d0bb12647fa0d72a287ff8c41c596adc27908640)
BibTeX
@misc{dc4303776a33e3,
title = {Radiometric Thermal Imaging Dataset of Laboratory Rats with Anatomical Segmentation Masks — arXiv:2608.03481},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.03481},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4303776a33e3; sha256 8b9c3bd39a050a916435c4c9d0bb12647fa0d72a287ff8c41c596adc27908640},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.03481. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Infrared thermography provides a contact-free, restraint-free method to record surface temperatures. It serves as a valuable marker for thermoregulatory responses in laboratory animal stress and pharmacology research. However, the analysis of these images is currently bottlenecked by the manual delineation of anatomical regions. To date, no public dataset has provided paired radiometric thermal frames of rats with pixel-level body-part labels. We present a dataset of 1,655 quality-controlled radiometric thermal frames from 25 laboratory rats. Each frame is paired with a dense four-class anatomical segmentation mask (background, head, body, and tail) and the raw $480 \times 640$ temperature matrix (rows $\times$ columns) in degrees Celsius. This ensures every label is registered directly to the physical temperature it describes rather than a color-mapped rendering. The frames originate from two pharmacological cohorts where interventions alter thermoregulation in opposite directions: ethanol, which induces peripheral vasodilation, and ketamine, which affects central thermoregulation. This provides a wide and physiologically diverse range of surface temperature regimes. Aggregated across the dataset, the per-class temperatures follow a head~$>$~body~$>$~tail ordering in physical units. To demonstrate that the data support pixel-level segmentation directly from the radiometric channel, we present an exploratory U-Net segmentation pipeline that attains a subject-level cross-validated mean intersection-over-union of $0.895 \pm 0.006$. The dataset provides a reuse-ready benchmark for thermal semantic segmentation and for downstream physiological and stress-phenotyping analyses. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-05 in eess.IV). Categorie arXiv: Image and Video Processing (eess.IV). Pagina del lavoro: https://arxiv.org/abs/2608.03481 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-31T13:15:43.126Z dalla pagina https://arxiv.org/catchup/eess.IV/2026-08-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).