Metraipolis › archive › dc_42b99fcdc687
Single-Mode Squeezing Using Degenerate Four-Wave Mixing in a Dual-Pump TWPA — arXiv:2611.00934
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.00934
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:47:24.541Z
- SHA-256 of the archived text
5979f36daf386193756fe75aad64b3290295505a325e161a2930fd42399ac94f- Stable URL of this page
https://metraipolis.com/documento/dc_42b99fcdc687
How to cite
Single-Mode Squeezing Using Degenerate Four-Wave Mixing in a Dual-Pump TWPA — arXiv:2611.00934 — arXiv (en), https://arxiv.org/abs/2611.00934 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_42b99fcdc687 (Metraipolis archive dc_42b99fcdc687, sha256 5979f36daf386193756fe75aad64b3290295505a325e161a2930fd42399ac94f)
BibTeX
@misc{dc42b99fcdc687,
title = {Single-Mode Squeezing Using Degenerate Four-Wave Mixing in a Dual-Pump TWPA — arXiv:2611.00934},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.00934},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_42b99fcdc687; sha256 5979f36daf386193756fe75aad64b3290295505a325e161a2930fd42399ac94f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00934. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Single-mode squeezing of the electromagnetic vacuum is a key resource for mode-selective noise reduction in quantum measurements. At microwave frequencies, single-mode squeezing is typically obtained by using Josephson and Traveling-Wave Parametric Amplifiers designed for three-wave mixing operation. In single-pump degenerate four-wave mixing, the coincidence of pump, signal, and idler frequencies complicates separation of the squeezed field from the strong pump. A dual-pump configuration enables degenerate operation while keeping both pumps spectrally separated from the squeezed mode. Here, we demonstrate single-mode squeezing in a flux-tunable, dual-pump Traveling-Wave Parametric Amplifier, employing reversed-Kerr phase matching. By independently calibrating the single-pump gains, we find that the strongest squeezing occurs along approximately balanced-gain trajectories, while the optimal squeezing does not necessarily correspond to the highest dual-pump gain. At flux biases $\Phi_\mathrm{ext}/\Phi_0 = 0.0$ and $0.5$, the minimum quadrature noise levels reach $-2.48 \pm 0.18~\mathrm{dB}$ and $-1.62 \pm 0.20~\mathrm{dB}$ relative to vacuum, respectively. These results establish the proposed architecture as a platform for single-mode squeezing in microwave continuous-variable quantum technologies.
Tema degli esploratori: fisica e astronomia (elenco arXiv quant-ph, nuovi lavori del giorno).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2611.00934 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T11:09:37.329Z dalla pagina https://arxiv.org/list/quant-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).