Metraipolis › archive › dc_41f94053c960

Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors — arXiv:2609.12184

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.12184
License (as archived)
CC0-1.0
Archived
2026-10-16T03:03:12.297Z
SHA-256 of the archived text
bbdb621903e3f307cea44bb2f703e2798fd2f6d21675adf46a46a0fda9515d2f
Stable URL of this page
https://metraipolis.com/documento/dc_41f94053c960

How to cite

Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors — arXiv:2609.12184 — arXiv (en), https://arxiv.org/abs/2609.12184 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_41f94053c960 (Metraipolis archive dc_41f94053c960, sha256 bbdb621903e3f307cea44bb2f703e2798fd2f6d21675adf46a46a0fda9515d2f)
BibTeX
@misc{dc41f94053c960,
  title = {Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors — arXiv:2609.12184},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.12184},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_41f94053c960; sha256 bbdb621903e3f307cea44bb2f703e2798fd2f6d21675adf46a46a0fda9515d2f},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.12184. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Experimental TCAD calibration is essential for predictive technology modeling of emerging oxide semiconductor transistors. However, it remains time-consuming and expert dependent because of model ambiguity. Multiple physical models and parameter sets can reproduce the same measured transfer characteristics, while local fitting alone cannot uniquely identify the underlying device physics. We present the first demonstration of an agentic TCAD calibration workflow for a fabricated bottom-gate In--W--O (BG-IWO) transistor. Starting from the measured transfer curve and device information, the workflow uses measurement--TCAD residuals and local sensitivity tests to select bounded parameter corrections or evaluate additional physical models, and accept only updates that improve device metrics. The LLM agent orchestrates the workflow, while Sentaurus governs the device physics. For the 2\%-W reference device, five agent-suggested updates yield a fixed calibrated model, reducing the multi-metric device objective $J$ by 14.3$\times$. Maximum $V_{\mathrm{th}}$/$I_{\mathrm{on}}$ errors are 36.1~mV/0.022 decade for varying-drain-bias tests and 46.2~mV/0.062 decade for varying-channel-length tests, demonstrating model transferability across bias and geometry rather than a local parameter fit. W-composition tests provide process-sensitive insight. This agentic workflow provides a faster route to model development for emerging device technologies.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-14 in cs.AI).
Categorie arXiv: Instrumentation and Detectors (physics.ins-det) ; Artificial Intelligence (cs.AI); Machine Learning (cs.LG); Applied Physics (physics.app-ph).
Pagina del lavoro: https://arxiv.org/abs/2609.12184 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T02:51:27.871Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-14?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).