Metraipolis › archive › dc_41c80965128f
MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA — arXiv:2611.01261
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.01261
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:09:53.988Z
- SHA-256 of the archived text
be20a6f0b35e464d513162e7e660c5fd6068faa2539502a7d6c95c461b6b3b1a- Stable URL of this page
https://metraipolis.com/documento/dc_41c80965128f
How to cite
MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA — arXiv:2611.01261 — arXiv (en), https://arxiv.org/abs/2611.01261 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_41c80965128f (Metraipolis archive dc_41c80965128f, sha256 be20a6f0b35e464d513162e7e660c5fd6068faa2539502a7d6c95c461b6b3b1a)
BibTeX
@misc{dc41c80965128f,
title = {MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA — arXiv:2611.01261},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.01261},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_41c80965128f; sha256 be20a6f0b35e464d513162e7e660c5fd6068faa2539502a7d6c95c461b6b3b1a},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.01261. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Spoken medical question answering can fail when automatic speech recognition (ASR) corrupts a clinically important term before retrieval. We present MedAstra, a framework that maps frozen WavLM speech representations through a lightweight adapter into a frozen E5 text embedding space. This enables a dense retrieval path that accepts a waveform without a query transcript. Retrieved passages and speech-linked textual metadata support answer generation with entity alternatives, diagnostic contrasts, relation heuristics, and bounded retrieval refinement. ASR-less refers to the initial speech retrieval interface; lexical retrieval, string-based entity correction, and the text generator require textual inputs. The deterministic speech embedding does not constitute a calibrated model of acoustic uncertainty. Reported retrieval results reach 87.6 Recall@10 for the speech-only retriever and 90.4 for the hybrid configuration, compared with 81.0 for transcript-first dense retrieval. Medical QA and ablations provide descriptive system comparisons, with input-provenance and evaluation limitations stated explicitly. We distinguish controlled synthetic acoustic tests from real clinical speech, qualify component attribution, and specify the remaining comparisons needed to assess speech-only QA and clinical generalization. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.CL, nuovi lavori del giorno). Categorie arXiv: Computation and Language (cs.CL). Pagina del lavoro: https://arxiv.org/abs/2611.01261 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T10:59:52.290Z dalla pagina https://arxiv.org/list/cs.CL/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).