Metraipolis › archive › dc_4040d611e2e7
LC-Resonance Placement Limits and Damping Recovery in Virtual-Admittance-Based Grid-Forming Inverter Control — arXiv:2610.39951
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.39951
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-01T03:00:46.216Z
- SHA-256 of the archived text
3bd6900b6fd9d01fd8df22bff0f6f28febd62b25b7268e7c2b13af8dd1e0d4e7- Stable URL of this page
https://metraipolis.com/documento/dc_4040d611e2e7
How to cite
LC-Resonance Placement Limits and Damping Recovery in Virtual-Admittance-Based Grid-Forming Inverter Control — arXiv:2610.39951 — arXiv (en), https://arxiv.org/abs/2610.39951 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4040d611e2e7 (Metraipolis archive dc_4040d611e2e7, sha256 3bd6900b6fd9d01fd8df22bff0f6f28febd62b25b7268e7c2b13af8dd1e0d4e7)
BibTeX
@misc{dc4040d611e2e7,
title = {LC-Resonance Placement Limits and Damping Recovery in Virtual-Admittance-Based Grid-Forming Inverter Control — arXiv:2610.39951},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.39951},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4040d611e2e7; sha256 3bd6900b6fd9d01fd8df22bff0f6f28febd62b25b7268e7c2b13af8dd1e0d4e7},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39951. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Compact LC-filter design and inner-loop control must be coordinated for stable grid-forming operation. This paper quantifies how current-loop proportional gain constrains LC-resonance placement in virtual-admittance-based dual-loop control with unity voltage-feedback decoupling (VFD) and capacitor-voltage active damping. Equivalent-impedance analysis identifies gain-dependent contraction of the positive-resistance region. Delayed inverter-current feedback opposes VFD-assisted damping above one-sixth of the sampling frequency. Simple proportional-path frequency shaping recovers an admissible effective-gain window while retaining unity VFD and leaving the resonant path unchanged. Reduced-model criteria, checked against the complete model, link window closure to a nominal resonance-placement limit near one-third of the sampling frequency under single-sampled single-update operation over the studied gain range. A 3-kVA prototype demonstrates an 83.3% LC-product reduction at comparable voltage and nominal current crossovers. A separate comparison with the same high-resonance filter demonstrates stable operation at 2.68 times the unshaped nominal current crossover. Output-impedance analysis and grid-connected tests identify additional grid-dependent gain constraints. Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2610.39951 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-01T02:25:30.753Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).