Metraipolis › archive › dc_3f547ae532f2
ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals — arXiv:2611.00011
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.00011
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:11:36.643Z
- SHA-256 of the archived text
88a1e3612005bb2c785b8e25d483aab96a0cdc81c90821a96baba46485d1ff61- Stable URL of this page
https://metraipolis.com/documento/dc_3f547ae532f2
How to cite
ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals — arXiv:2611.00011 — arXiv (en), https://arxiv.org/abs/2611.00011 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3f547ae532f2 (Metraipolis archive dc_3f547ae532f2, sha256 88a1e3612005bb2c785b8e25d483aab96a0cdc81c90821a96baba46485d1ff61)
BibTeX
@misc{dc3f547ae532f2,
title = {ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals — arXiv:2611.00011},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.00011},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3f547ae532f2; sha256 88a1e3612005bb2c785b8e25d483aab96a0cdc81c90821a96baba46485d1ff61},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00011. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Accurate heart rate (HR) and interbeat interval (IBI) estimation from wearable electrocardiogram (ECG) is essential for continuous physiological monitoring, but motion artifacts can create false QRS-like peaks and obscure true R-peaks. Conventional detectors and local interval-repair rules process detections independently and may become unreliable when several consecutive beats are corrupted. We present ARTA (Artifact-Robust Temporal Alignment), a graph-based combinatorial framework that estimates the heartbeat sequence through constrained temporal optimization. ARTA combines candidates from multiple ECG detectors, represents them as nodes in a directed acyclic graph and connects candidates through physiologically plausible RR intervals. Candidate confidence uses detector agreement and local ECG quality, while history-dependent transition costs capture recent IBI consistency and a soft heart-rate prior. Beam-search dynamic programming selects a coherent low-cost path across the recording, suppressing false detections and recovering missed beats when plausible auxiliary candidates are available. On the IEEE Signal Processing Cup exercise dataset with electrode-motion artifacts from -2 to 12 dB, ARTA achieved an HR mean absolute error of 1.79 beats per minute, 54% lower than the strongest single-detector baseline, with 92.38% of windows within +/-5 beats per minute, an R-peak F1 score of 0.95, and an IBI mean absolute error of 6.52 ms. Cross-dataset evaluation on the European ST-T Database further assessed transfer to long clinical ambulatory recordings and a label-free reliability analysis examined conditional performance without using reference annotations for segment selection. ARTA is single-channel, training-free, interpretable and computationally lightweight, operating approximately 27 times faster than real time with peak memory below 2.1 MB in a single-thread CPU simulation. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.CL, nuovi lavori del giorno). Categorie arXiv: Signal Processing (eess.SP) ; Computation and Language (cs.CL); Mathematical Software (cs.MS). Pagina del lavoro: https://arxiv.org/abs/2611.00011 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T10:59:52.372Z dalla pagina https://arxiv.org/list/cs.CL/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).