Metraipolis › archive › dc_3f4757cf6c8e
FRAC-MAS: A Safe and Explainable Multi-Agent System for Fracture Diagnosis — arXiv:2608.28662
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28662
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T07:43:48.195Z
- SHA-256 of the archived text
7f7a1a6a16a1f75d1e14b40536bd03faeba3833c74f3124888ea83991492e522- Stable URL of this page
https://metraipolis.com/documento/dc_3f4757cf6c8e
How to cite
FRAC-MAS: A Safe and Explainable Multi-Agent System for Fracture Diagnosis — arXiv:2608.28662 — arXiv (en), https://arxiv.org/abs/2608.28662 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3f4757cf6c8e (Metraipolis archive dc_3f4757cf6c8e, sha256 7f7a1a6a16a1f75d1e14b40536bd03faeba3833c74f3124888ea83991492e522)
BibTeX
@misc{dc3f4757cf6c8e,
title = {FRAC-MAS: A Safe and Explainable Multi-Agent System for Fracture Diagnosis — arXiv:2608.28662},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28662},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3f4757cf6c8e; sha256 7f7a1a6a16a1f75d1e14b40536bd03faeba3833c74f3124888ea83991492e522},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28662. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Fracture detection and its clinical interpretability see notable improvements when deep vision models are integrated with agentic AI architectures. While deep learning models achieve high diagnostic performance, their black-box nature limits clinical adoption. We propose FRAC-MAS, an agentic AI system for automated, explainable, and safe bone fracture detection. The framework combines a stacked ensemble of four vision models with conformal prediction to produce statistically grounded differential diagnoses, while a multi-agent workflow performs independent verification, retrieves clinical guidelines, and generates patient-friendly reports. A pipeline-depth ablation study confirms that our multi-agent critic triages 86.6% of cases into a high-confidence auto-confirmed cohort while escalating uncertain cases, outperforming a single-agent baseline. Patient preference studies against Llama, MedGemma, and Gemini further demonstrate significantly more comprehensible clinical reports. These results suggest that integrating multi-agent critics with conformal guarantees enables safer radiology triage while preserving clinician oversight. More broadly, FRAC-MAS demonstrates how cooperative agentic architectures can serve as auditable, human-in-the-loop decision support systems for safety-critical healthcare. Our code is available at this https URL , and the website is available at this https URL . Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-01 in cs.AI). Categorie arXiv: Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2608.28662 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T07:28:26.474Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).