Metraipolis › archive › dc_3e6922dc7589

Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTI — arXiv:2611.01405

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.01405
License (as archived)
CC0-1.0
Archived
2026-11-03T11:55:08.814Z
SHA-256 of the archived text
35ef1fe2db0d595f5ed4927a10999c84877a9a1f82242065bd84394cab916f98
Stable URL of this page
https://metraipolis.com/documento/dc_3e6922dc7589

How to cite

Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTI — arXiv:2611.01405 — arXiv (en), https://arxiv.org/abs/2611.01405 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3e6922dc7589 (Metraipolis archive dc_3e6922dc7589, sha256 35ef1fe2db0d595f5ed4927a10999c84877a9a1f82242065bd84394cab916f98)
BibTeX
@misc{dc3e6922dc7589,
  title = {Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTI — arXiv:2611.01405},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.01405},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3e6922dc7589; sha256 35ef1fe2db0d595f5ed4927a10999c84877a9a1f82242065bd84394cab916f98},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.01405. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

High-performance head-only gradient systems can substantially reduce echo spacing (ESP) in echo-planar imaging (EPI), but the resulting encoding speed is typically used to shorten readouts and reduce distortion. Here, we instead leverage the increased echo budget to enable denser k-space sampling and higher simultaneous-multislice (SMS) acceleration in SMS-EPI and SMS-EPTI. Fast k-space traversal with denser ky-kz sampling is achieved using peripheral nerve stimulation (PNS)-optimized gradient waveforms, while high-quality reconstruction is obtained using field-correcting GRAPPA (FCG). The resulting ESPs on MAGNUS 3T and Impulse 7T are approximately half those of high-performance whole-body systems, enabling approximately 2-fold higher multiband (MB) acceleration. This facilitates high-quality 2.5-mm isotropic whole-brain resting-state fMRI at 7T with MB28 and a repetition time (TR) of 123 ms.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.SP, nuovi lavori del giorno).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2611.01405 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T11:15:41.210Z dalla pagina https://arxiv.org/list/eess.SP/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).