Metraipolis › archive › dc_3e23c4c16cb7
Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction — arXiv:2609.22105
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.22105
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T07:08:02.000Z
- SHA-256 of the archived text
ab930c5708c1f8968f513f7dbb9698b0b3983a85a910d0ab568b9cf9c45daf76- Stable URL of this page
https://metraipolis.com/documento/dc_3e23c4c16cb7
How to cite
Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction — arXiv:2609.22105 — arXiv (en), https://arxiv.org/abs/2609.22105 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3e23c4c16cb7 (Metraipolis archive dc_3e23c4c16cb7, sha256 ab930c5708c1f8968f513f7dbb9698b0b3983a85a910d0ab568b9cf9c45daf76)
BibTeX
@misc{dc3e23c4c16cb7,
title = {Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction — arXiv:2609.22105},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.22105},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3e23c4c16cb7; sha256 ab930c5708c1f8968f513f7dbb9698b0b3983a85a910d0ab568b9cf9c45daf76},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.22105. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Automatic sleep staging from polysomnography (PSG) is a well-studied task, but PSG itself is expensive, clinic-based, and burdensome to manually score, which limits its use for long-term or at-home monitoring. Most existing sleep-staging foundation models are evaluated using the full PSG montage. We instead ask how much of that montage is actually necessary. We evaluate six sleep staging models on the Multi-Ethnic Study of Atherosclerosis (MESA) PSG dataset across three signal conditions: electroencephalography (EEG), electrocardiography (ECG), and their combination (EEG+ECG). This is motivated by edge-cloud deployment, where EEG requires a clinic-grade scalp electrode, whereas ECG is already captured by consumer wearables. We test state-of-the-art foundation models such as SleepFM with an encoder trained from scratch on MESA, alongside BIOT, MOMENT, LaBraM, a base-scale Vision Transformer (ViT-B) reimplementation of SensorLM trained from scratch, and YASA, spanning EEG-pretrained, general-time-series, from-scratch, and classical non-learned approaches. No model architecture is modified from its original form; SensorLM's encoder is reimplemented only in PyTorch. For EEG-only staging, BIOT achieves the best result with a macro~F1 of 0.7237, followed by LaBraM (0.6835) and SleepFM from scratch (0.6582). Across the five models capable of ECG-only staging, switching from EEG to ECG costs between 0.2798 (MOMENT) and 0.4151 (BIOT) macro~F1, averaging 0.3531, while cutting the raw channel data rate to a third. Adding ECG to EEG provides no gain for most models. These results show that EEG carries most of the sleep-staging signal, quantify the consistent accuracy cost of the wearable-compatible alternative, and demonstrate that sleep-relevant pretraining transfers well to MESA. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-22 in cs.LG). Categorie arXiv: Signal Processing (eess.SP) ; Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2609.22105 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T06:58:09.473Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).