Metraipolis › archive › dc_3dfba0b58721
PredRA: Fast Medical Image Translation by Deterministic Component Extraction and Controlled Stochastic Refinement — arXiv:2609.31912
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.31912
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T23:50:40.420Z
- SHA-256 of the archived text
aff48917f00766934b0a19c3ff6e4a18b7c2268487dca4c27cad9e89efbb3a3c- Stable URL of this page
https://metraipolis.com/documento/dc_3dfba0b58721
How to cite
PredRA: Fast Medical Image Translation by Deterministic Component Extraction and Controlled Stochastic Refinement — arXiv:2609.31912 — arXiv (en), https://arxiv.org/abs/2609.31912 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3dfba0b58721 (Metraipolis archive dc_3dfba0b58721, sha256 aff48917f00766934b0a19c3ff6e4a18b7c2268487dca4c27cad9e89efbb3a3c)
BibTeX
@misc{dc3dfba0b58721,
title = {PredRA: Fast Medical Image Translation by Deterministic Component Extraction and Controlled Stochastic Refinement — arXiv:2609.31912},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.31912},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3dfba0b58721; sha256 aff48917f00766934b0a19c3ff6e4a18b7c2268487dca4c27cad9e89efbb3a3c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31912. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Strongly paired medical image translation contains a substantial component that can be predicted directly from the source. The current reality is that pure deterministic prediction can smooth away fine detail, while generative models can recover detail but may also introduce unnecessary or potentially harmful variation. We propose PredRA, a fast framework that uses the deterministic prediction as a stable reference and further extracts additional deterministic components from the residual during generative refinement, thereby improving fidelity while maintaining perceptual quality. The goal is simple: we view the entire residual-based generative process as an optimization problem and derive a practical solution that recovers useful residual detail through controlled refinement while keeping the prediction close to the paired target. Mechanism studies further show that useful residual information follows structured patterns, but its usefulness is difficult to estimate reliably at the voxel level. We therefore globally control how much of the residual refinement is added to the deterministic prediction, thereby reducing the accumulation of unnecessary uncertainty. PredRA therefore combines deterministic component extraction with controlled stochastic refinement for fast, fidelity-preserving, and perceptually strong medical image translation. We validate the approach across multiple real-world datasets, showing that controlled refinement improves fidelity to the paired target compared with full residual refinement while retaining much of the perceptual benefit of generative modeling. PredRA achieves competitive or superior performance to substantially larger state-of-the-art models with 1.4-11.9x fewer total parameters and 3.1-26.2x fewer trainable parameters, while its 32-step flow sampler requires 31.25x fewer sampling steps than the matched 1000-step DDPM. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.31912 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T23:29:26.948Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).