Metraipolis › archive › dc_3db1e72e2769

Flow Matching-Based PET Image Reconstruction — arXiv:2608.20112

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.20112
License (as archived)
CC0-1.0
Archived
2026-10-18T12:04:59.406Z
SHA-256 of the archived text
53e9b77014c7f86363eadcec694e9a8be2dcd210d31653d2b6151f64db713fde
Stable URL of this page
https://metraipolis.com/documento/dc_3db1e72e2769

How to cite

Flow Matching-Based PET Image Reconstruction — arXiv:2608.20112 — arXiv (en), https://arxiv.org/abs/2608.20112 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3db1e72e2769 (Metraipolis archive dc_3db1e72e2769, sha256 53e9b77014c7f86363eadcec694e9a8be2dcd210d31653d2b6151f64db713fde)
BibTeX
@misc{dc3db1e72e2769,
  title = {Flow Matching-Based PET Image Reconstruction — arXiv:2608.20112},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.20112},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3db1e72e2769; sha256 53e9b77014c7f86363eadcec694e9a8be2dcd210d31653d2b6151f64db713fde},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.20112. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-21 in cs.CV).
Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV); Medical Physics (physics.med-ph).
Pagina del lavoro: https://arxiv.org/abs/2608.20112 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T12:01:57.769Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).