Photoacoustic tomography versus cone-beam computed tomography versus micro-computed tomography: Accuracy of 3D reconstructions of human teeth — Europe PMC PMID:36534651

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/36534651
DOI
10.1371/journal.pone.0274818
License (as archived)
CC0-1.0
Archived
2026-10-09T22:25:20.169Z
SHA-256 of the archived text
cc9dc713e089f3b3dc063cbf52af1e50b005ca7d030b3b499c47345592bfa478
Stable URL of this page
https://metraipolis.com/documento/dc_3d22b7884e65

How to cite

Photoacoustic tomography versus cone-beam computed tomography versus micro-computed tomography: Accuracy of 3D reconstructions of human teeth — Europe PMC PMID:36534651 — Europe PMC (en), https://europepmc.org/article/MED/36534651 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3d22b7884e65 (Metraipolis archive dc_3d22b7884e65, sha256 cc9dc713e089f3b3dc063cbf52af1e50b005ca7d030b3b499c47345592bfa478)
BibTeX
@misc{dc3d22b7884e65,
  title = {Photoacoustic tomography versus cone-beam computed tomography versus micro-computed tomography: Accuracy of 3D reconstructions of human teeth — Europe PMC PMID:36534651},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/36534651},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3d22b7884e65; sha256 cc9dc713e089f3b3dc063cbf52af1e50b005ca7d030b3b499c47345592bfa478},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/36534651. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Objectives: In this in-vitro study, teeth were imaged using photoacoustic tomography (PAT), cone-beam computed tomography (CBCT), and micro-computed tomography (μ-CT). The study had aim: to identify the best wavelength for PAT images to determine the accuracy of the three imaging methods, and to determine whether PAT images of teeth can achieve acceptable reconstruction quality. Methods: Nineteen human mandibular single-rooted incisors were extracted from patients with trauma or periodontitis. To determine the best wavelength for acquiring photoacoustic images, all 19 teeth were scanned in vitro with PAT, using different laser wavelengths between 680 and 960 nm. The images were analyzed using image analysis software. To assess the accuracy of PAT and compare it with the accuracy of CBCT, each tooth was also scanned in vitro using CBCT and the reference standard technique of μ-CT. Subsequently, three different three-dimensional models, one for each imaging technique, were created for each tooth. Finally, the three different three-dimensional models acquired for the same tooth were matched and analyzed regarding volume and surface. Results: The highest quality tooth images were achieved using the 680 nm wavelength, which showed the best contrast ratio. The full geometry of the dental root (μ-CT compared with PAT) could be visualized with relative standard deviations of 0.12 mm for the surface and -7.33 mm3 for the volume (n = 19). The full geometry of the dental root (μ-CT compared with CBCT) could be visualized with relative standard deviations of 0.06 mm for the surface and -14.56 mm3 for the volume (n = 19). The difference between the PAT-μ-CT group and CBCT-μ-CT group regarding the total average of the root surface area was not significant (p>0.06). Conclusion: Images, which were acquired using PAT at 680nm showed the best contrast ration, enabling the identification of dentin, cementum and the dental pulp. No significant differences were found between the PAT-μ-CT group and CBCT-μ-CT group regarding the total average of the RSA and the total volume. Thus, three-dimensional reconstructions based on in-vitro PAT are already of acceptable reconstruction quality.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2022 (prima pubblicazione 2022-12-19).
Identificativi: PMID 36534651 · PMCID PMC9762560 · DOI 10.1371/journal.pone.0274818.
Descrittori MeSH principali: Imaging, Three-Dimensional; Cone-Beam Computed Tomography.
Pagina: https://europepmc.org/article/MED/36534651 — https://doi.org/10.1371/journal.pone.0274818. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-09T22:06:38.740Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.