Metraipolis › archive › dc_3cdb75fd2135

Distortion correction of diffusion weighted MRI without reverse phase-encoding scans or field-maps — Europe PMC PMID:32735601

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/32735601
DOI
10.1371/journal.pone.0236418
License (as archived)
CC0-1.0
Archived
2026-11-07T22:23:56.149Z
SHA-256 of the archived text
b5e402b280f384ada6ccd57d53322e5529f7d2e7de5635d4b3c3bfa4f26c9663
Stable URL of this page
https://metraipolis.com/documento/dc_3cdb75fd2135

How to cite

Distortion correction of diffusion weighted MRI without reverse phase-encoding scans or field-maps — Europe PMC PMID:32735601 — Europe PMC (en), https://europepmc.org/article/MED/32735601 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3cdb75fd2135 (Metraipolis archive dc_3cdb75fd2135, sha256 b5e402b280f384ada6ccd57d53322e5529f7d2e7de5635d4b3c3bfa4f26c9663)
BibTeX
@misc{dc3cdb75fd2135,
  title = {Distortion correction of diffusion weighted MRI without reverse phase-encoding scans or field-maps — Europe PMC PMID:32735601},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/32735601},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3cdb75fd2135; sha256 b5e402b280f384ada6ccd57d53322e5529f7d2e7de5635d4b3c3bfa4f26c9663},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/32735601. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Diffusion magnetic resonance images may suffer from geometric distortions due to susceptibility induced off resonance fields, which cause geometric mismatch with anatomical images and ultimately affect subsequent quantification of microstructural or connectivity indices. State-of-the art diffusion distortion correction methods typically require data acquired with reverse phase encoding directions, resulting in varying magnitudes and orientations of distortion, which allow estimation of an undistorted volume. Alternatively, additional field maps acquisitions can be used along with sequence information to determine warping fields. However, not all imaging protocols include these additional scans and cannot take advantage of state-of-the art distortion correction. To avoid additional acquisitions, structural MRI (undistorted scans) can be used as registration targets for intensity driven correction. In this study, we aim to (1) enable susceptibility distortion correction with historical and/or limited diffusion datasets that do not include specific sequences for distortion correction and (2) avoid the computationally intensive registration procedure typically required for distortion correction using structural scans. To achieve these aims, we use deep learning (3D U-nets) to synthesize an undistorted b0 image that matches geometry of structural T1w images and intensity contrasts from diffusion images. Importantly, the training dataset is heterogenous, consisting of varying acquisitions of both structural and diffusion. We apply our approach to a withheld test set and show that distortions are successfully corrected after processing. We quantitatively evaluate the proposed distortion correction and intensity-based registration against state-of-the-art distortion correction (FSL topup). The results illustrate that the proposed pipeline results in b0 images that are geometrically similar to non-distorted structural images, and more closely match state-of-the-art correction with additional acquisitions. In addition, we show generalizability of the proposed approach to datasets that were not in the original training / validation / testing datasets. These datasets included varying populations, contrasts, resolutions, and magnitudes and orientations of distortion and show efficacious distortion correction. The method is available as a Singularity container, source code, and an executable trained model to facilitate evaluation.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2020 (prima pubblicazione 2020-07-31).
Identificativi: PMID 32735601 · PMCID PMC7394453 · DOI 10.1371/journal.pone.0236418.
Pagina: https://europepmc.org/article/MED/32735601 — https://doi.org/10.1371/journal.pone.0236418. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-11-07T22:20:09.288Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.