Metraipolis › archive › dc_3cc7ab0bf233
Finite-Data Safety Informativity Under Dynamic Asymmetric Actuation — arXiv:2610.01820
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.01820
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T12:30:36.146Z
- SHA-256 of the archived text
3383d9505f585ddf287b662f9e4a84159eed1d7cc667632539348dfaddd9bef4- Stable URL of this page
https://metraipolis.com/documento/dc_3cc7ab0bf233
How to cite
Finite-Data Safety Informativity Under Dynamic Asymmetric Actuation — arXiv:2610.01820 — arXiv (en), https://arxiv.org/abs/2610.01820 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3cc7ab0bf233 (Metraipolis archive dc_3cc7ab0bf233, sha256 3383d9505f585ddf287b662f9e4a84159eed1d7cc667632539348dfaddd9bef4)
BibTeX
@misc{dc3cc7ab0bf233,
title = {Finite-Data Safety Informativity Under Dynamic Asymmetric Actuation — arXiv:2610.01820},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.01820},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3cc7ab0bf233; sha256 3383d9505f585ddf287b662f9e4a84159eed1d7cc667632539348dfaddd9bef4},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.01820. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
When the system model is not fully known, measurement error and limited excitation can leave several models consistent with the same finite data. A command judged safe for one model may fail for another, while limited control authority can prevent the corrective action needed to preserve safety. To ensure safety under model uncertainty and asymmetric input limits, we develop a finite-data certificate that determines whether a command can enforce a prescribed safety inequality. For a linearly parameterized safety channel with exactly known regressors and bounded aggregate residual error, we derive a support formula for the worst-case safety contribution of all data-consistent models. The formula identifies the regressor directions that admit a finite bound, allowing rank-deficient records to contribute to safety certification. Using certified componentwise bounds on actuator tracking error yields an affine inequality with a necessary and sufficient test for pointwise command feasibility. The affine inequality reduces computation of the closest certified command to a scalar root-finding problem. It also yields a closed-form gate that selects the largest certified fraction of a prescribed command segment. The proposed certificate guarantees output safety within its operating domain, provided the feedback is locally Lipschitz and the uncertainty bounds remain valid. Domain retention and full-state continuation extend this guarantee to all time. A vehicle study demonstrates that output safety can be certified from finite measurements in a safety-critical setting with model and actuator uncertainty. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-10-02 in eess.SY). Categorie arXiv: Systems and Control (eess.SY) ; Robotics (cs.RO); Dynamical Systems (math.DS). Pagina del lavoro: https://arxiv.org/abs/2610.01820 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T12:03:07.620Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-10-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).