Metraipolis › archive › dc_3ab8878045d8

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking — arXiv:2609.09577

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.09577
License (as archived)
CC0-1.0
Archived
2026-10-16T07:25:44.425Z
SHA-256 of the archived text
a30c6bc4b70e673508abda38a2abfa46b1d0819cb1e0f7d1e1bb4ca3f74e171b
Stable URL of this page
https://metraipolis.com/documento/dc_3ab8878045d8

How to cite

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking — arXiv:2609.09577 — arXiv (en), https://arxiv.org/abs/2609.09577 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3ab8878045d8 (Metraipolis archive dc_3ab8878045d8, sha256 a30c6bc4b70e673508abda38a2abfa46b1d0819cb1e0f7d1e1bb4ca3f74e171b)
BibTeX
@misc{dc3ab8878045d8,
  title = {Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking — arXiv:2609.09577},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.09577},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3ab8878045d8; sha256 a30c6bc4b70e673508abda38a2abfa46b1d0819cb1e0f7d1e1bb4ca3f74e171b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.09577. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-10 in cs.AI).
Categorie arXiv: Image and Video Processing (eess.IV) ; Artificial Intelligence (cs.AI); Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.09577 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T07:00:16.325Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-10?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).