Metraipolis › archive › dc_3a62fc904085

Optimal Sampling and Noise Mitigation for Vocal Fold Kinematics in High-Speed Videoendoscopy — arXiv:2610.40697

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.40697
License (as archived)
CC0-1.0
Archived
2026-11-03T06:00:54.079Z
SHA-256 of the archived text
71efcc524ba5778a2e96677cf139a6742410c2d61d89a269665171c2def7b4f6
Stable URL of this page
https://metraipolis.com/documento/dc_3a62fc904085

How to cite

Optimal Sampling and Noise Mitigation for Vocal Fold Kinematics in High-Speed Videoendoscopy — arXiv:2610.40697 — arXiv (en), https://arxiv.org/abs/2610.40697 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3a62fc904085 (Metraipolis archive dc_3a62fc904085, sha256 71efcc524ba5778a2e96677cf139a6742410c2d61d89a269665171c2def7b4f6)
BibTeX
@misc{dc3a62fc904085,
  title = {Optimal Sampling and Noise Mitigation for Vocal Fold Kinematics in High-Speed Videoendoscopy — arXiv:2610.40697},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.40697},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3a62fc904085; sha256 71efcc524ba5778a2e96677cf139a6742410c2d61d89a269665171c2def7b4f6},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.40697. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Objectives: High-Speed Videoendoscopy glottal area waveforms conflate lateral fold excursion with longitudinal opening, precluding direct estimation of velocity, acceleration, and left-right asymmetry. Displacement waveforms preserve these quantities but are susceptible to spatial quantization and temporal sampling errors. We characterize these errors, evaluate reduction via Kalman smoothing and temporal interpolation, and determine optimal frame rate bounds relative to pixel excursion, speed quotient (SQ), and open quotient (OQ). Methods: Sampling theory was used to derive analytical frame-rate bounds required for kinematic feature fidelity. Kalman smoothing was compared with FFT-based denoising, paired with sinc or spline interpolation. Interpolation was evaluated on 4000 fps recordings (N=55) downsampled and reconstructed. A 16000 fps dataset (N=12) served as reference for noise reduction across 2000-8000 fps downsampled waveforms evaluated on peak displacement, velocity, OQ, and SQ. Results: Sinc interpolation yielded lower median mean absolute error than spline (0.29 vs 0.52 pixels), with 85% of recordings (47/55) versus 45% (25/55) below 0.5 pixels. For kinematic feature estimation (N=12), Kalman-sinc outperformed FFT-sinc in 75% of feature-by-frame-rate pairings. Conclusion: Computing kinematic features without artifacts requires joint consideration of temporal and spatial resolution. Kalman-sinc preprocessing at 8000 fps is recommended for velocity and SQ measures. Peak lateral displacement can be measured at 2000 fps, while OQ requires 4000 fps for typical spatial resolutions (9-14 pixels maximum excursion). Pixel excursion should be reported alongside kinematic measures to contextualize data reliability.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.IV, nuovi lavori del giorno).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2610.40697 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T05:43:04.555Z dalla pagina https://arxiv.org/list/eess.IV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).