Metraipolis › archive › dc_3a3876797f0e
TotalSynth: Robust Whole-Body Synthetic CT from MRI and CBCT — arXiv:2609.13838
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.13838
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T01:52:48.463Z
- SHA-256 of the archived text
637e2fde098f6931a14a226c692750b8a7325e41bb694ed9d6f50c0ffc9a3c79- Stable URL of this page
https://metraipolis.com/documento/dc_3a3876797f0e
How to cite
TotalSynth: Robust Whole-Body Synthetic CT from MRI and CBCT — arXiv:2609.13838 — arXiv (en), https://arxiv.org/abs/2609.13838 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3a3876797f0e (Metraipolis archive dc_3a3876797f0e, sha256 637e2fde098f6931a14a226c692750b8a7325e41bb694ed9d6f50c0ffc9a3c79)
BibTeX
@misc{dc3a3876797f0e,
title = {TotalSynth: Robust Whole-Body Synthetic CT from MRI and CBCT — arXiv:2609.13838},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.13838},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3a3876797f0e; sha256 637e2fde098f6931a14a226c692750b8a7325e41bb694ed9d6f50c0ffc9a3c79},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.13838. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Purpose: To develop and evaluate TotalSynth, a reusable pretrained framework for whole-body synthetic CT (sCT) generation from MRI and cone-beam CT (CBCT) images. Materials and Methods: In this retrospective technical study, the dataset was assembled between 2020 and 2026 from SynthRAD challenge data, four prostate cohorts, and BIC-MAC. After registration quality control, 1450 of 1800 public challenge pairs were retained; 350 were excluded for insufficient registration quality or major source/CT mismatch. The corpus also included 84 additional prostate MRI/CT and 60 external BIC-MAC MRI/CT cases. Three 5-fold model families were evaluated with image-domain, anatomy-aware, registration-based, and uncertainty metrics. Age and sex were not consistently available across public datasets. Results: The released MRI-to-CT model achieved an overall MAE of 67.49 HU, SSIM of 0.920, and PSNR of 29.28 dB. The CBCT-to-CT model achieved an overall MAE of 53.55 HU, SSIM of 0.939, and PSNR of 32.09 dB. The unified model maintained similar performance on MRI inputs (MAE, 67.68 HU) and CBCT inputs (MAE, 54.22 HU). On external BIC-MAC data, MRI-to-CT MAE was 100.91 HU without fine-tuning and 62.21 HU after fine-tuning. Conclusion: TotalSynth provides reusable MRI- and CBCT-based CT synthesis models with broad anatomical coverage, while external evaluation highlights the need for local validation and optional fine-tuning under domain shift. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-15 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.13838 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T01:25:23.537Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).