Metraipolis › archive › dc_39a4f519ff6a
When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation — arXiv:2609.21412
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.21412
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T02:27:29.502Z
- SHA-256 of the archived text
506a579000d76eb7ab39952fbe5cfae46d7fe04e2f40f80614d61384c549c960- Stable URL of this page
https://metraipolis.com/documento/dc_39a4f519ff6a
How to cite
When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation — arXiv:2609.21412 — arXiv (en), https://arxiv.org/abs/2609.21412 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_39a4f519ff6a (Metraipolis archive dc_39a4f519ff6a, sha256 506a579000d76eb7ab39952fbe5cfae46d7fe04e2f40f80614d61384c549c960)
BibTeX
@misc{dc39a4f519ff6a,
title = {When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation — arXiv:2609.21412},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.21412},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_39a4f519ff6a; sha256 506a579000d76eb7ab39952fbe5cfae46d7fe04e2f40f80614d61384c549c960},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.21412. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningful alternative: parameter-frozen inference enhancement(PIE). We use a source-trained segmenter that learns about anatomy-preserving scale and flip views, maps their predictions back to the native location, and averages the probabilities. We do not modify the weights of the model or the normalization statistics. On a cardiac MRI stream from M\&Ms, which is trained on vendor A and evaluated sequentially on vendors B, C, and D, PIE has 0.7786 mean Dice, compared to 0.7680 for source-only inference and 0.7388--0.7416 for five other online-adaptation baselines. The controlled ablations show that performance saturates at 28 views, and confidence weighting, class-prior correction, connected-component filtering, morphological refinement, and inter-slice smoothing have no effect or cause negative transfer. Qualitative results on cardiac MRI and fundus images are also consistent with the frozen ensemble keeping thinner and nested anatomical structures. These results provide a strong, stable baseline for medical CTTA and expose an important failure mode: adaptation and handcrafted refinement can be less reliable than carefully designed inference. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-21 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.21412 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-10T02:07:36.052Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).