Choosing an energy-efficient software architecture for building system diagnostic support — arXiv:2610.06444 — arXiv, https://arxiv.org/abs/2610.06444 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_39433708b477 (Metraipolis archive dc_39433708b477, sha256 213112371947a67a534ea1b9ee130afa0470e326e6c80a4dec7fb392eba6f7a3)
BibTeX
@misc{dc39433708b477,
title = {Choosing an energy-efficient software architecture for building system diagnostic support — arXiv:2610.06444},
howpublished = {arXiv},
url = {https://arxiv.org/abs/2610.06444},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_39433708b477; sha256 213112371947a67a534ea1b9ee130afa0470e326e6c80a4dec7fb392eba6f7a3},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv, https://arxiv.org/abs/2610.06444. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Around 30\% of global energy expenditure can be attributed to the building sector, where a large portion of energy-consumption could be avoided by repairing existing faults. Fault detection and diagnosis (FDD) software addresses this issue; however, its creation and operation also have an environmental impact. The magnitude of this impact is influenced by the diagnosis architecture, as different architectures and methods have different energy demands. Yet, simply considering the energy consumed by the software itself is not sufficient to assess its overall environmental impact, since the diagnostic performance, e.g., number of detected faults or number of faults missed, also contributes to its ecological footprint. In this paper, we propose an energy-consumption model that considers FDD performance and energy spend directly by the diagnosis software. In an initial experiment, we compare several FDD architecture families, i.e., rule-based, model-based, classical machine learning, and large-language-model-based, in simulation using performance and energy-consumption values collected from prior literature. The results show that considering the computational energy and accuracy of FDD can change the relative benefit of the different approaches. Computationally efficient machine learning methods, such as random forest, provide the largest net savings on smaller buildings, whereas more resource-intensive approaches, such as fine-tuned large language models, become advantageous as building size increases. Our findings suggest that overall energy efficiency depends not only on the computational demand of the FDD software, but also on its diagnostic performance and the scale of the building. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Software Engineering (cs.SE) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2610.06444 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-06T05:24:06.159Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).