Analysis and modeling of coolants and coolers for specimen transportation — Europe PMC PMID:32302335 — Europe PMC (en), https://europepmc.org/article/MED/32302335 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_38a8a44308c0 (Metraipolis archive dc_38a8a44308c0, sha256 fd8da93788b5b26b358eb6a2dde8608a1d463ffec52c418bc23109334aae317d)
BibTeX
@misc{dc38a8a44308c0,
title = {Analysis and modeling of coolants and coolers for specimen transportation — Europe PMC PMID:32302335},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/32302335},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_38a8a44308c0; sha256 fd8da93788b5b26b358eb6a2dde8608a1d463ffec52c418bc23109334aae317d},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/32302335. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Maintaining cold chain while transporting medical supplies and samples is difficult in remote settings. Failure to maintain temperature requirements can lead to degraded sample quality and inaccuracies in sample analysis. We performed a systematic analysis on different types of transport coolers (polystyrene foam, injection-molded, and rotational molded) and transport coolants (ice, cold packs, frozen water bottles) frequently in use in many countries. Polystyrene foam coolers stayed below our temperature threshold (6°C) longer than almost all other types of coolers, but were not durable. Injection-molded coolers were durable, but warmed to 6°C the quickest. Rotational molded coolers were able to keep temperatures below our threshold for 24 hours longer than injection molded coolers and were highly durable. Coolant systems were evaluated in terms of cost and their ability to maintain cold temperatures. Long lasting commercial cold packs were found to be less cost effective and were below freezing for the majority of the testing period. Frozen plastic water bottles were found to be a reusable and economical choice for coolant and were only below freezing briefly. Finally, we modeled the coolers performance at maintaining internal temperatures below 6°C and built a highly accurate linear model to predict how long a cooler will remain below 6°C. We believe this data may be useful in the planning and design of specimen transportation systems in the field, particularly in remote or resource limited settings. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2020 (prima pubblicazione 2020-04-17). Identificativi: PMID 32302335 · PMCID PMC7164660 · DOI 10.1371/journal.pone.0231093. Descrittori MeSH principali: Cost-Benefit Analysis. Pagina: https://europepmc.org/article/MED/32302335 — https://doi.org/10.1371/journal.pone.0231093. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-08T23:44:34.547Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.