Metraipolis › archive › dc_3897024da056
ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation — arXiv:2609.23950
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.23950
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T07:08:38.652Z
- SHA-256 of the archived text
274e7554b56ffdcbe4d933809da3f46fa4fd2f31a5c087a14820aedbbe004208- Stable URL of this page
https://metraipolis.com/documento/dc_3897024da056
How to cite
ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation — arXiv:2609.23950 — arXiv (en), https://arxiv.org/abs/2609.23950 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3897024da056 (Metraipolis archive dc_3897024da056, sha256 274e7554b56ffdcbe4d933809da3f46fa4fd2f31a5c087a14820aedbbe004208)
BibTeX
@misc{dc3897024da056,
title = {ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation — arXiv:2609.23950},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.23950},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3897024da056; sha256 274e7554b56ffdcbe4d933809da3f46fa4fd2f31a5c087a14820aedbbe004208},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.23950. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-22 in cs.LG). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Medical Physics (physics.med-ph). Pagina del lavoro: https://arxiv.org/abs/2609.23950 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T06:58:09.611Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).