Metraipolis › archive › dc_385a7b4c6918

Traceprop: Training Data Attribution in a Single Pass — arXiv:2609.32380

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.32380
License (as archived)
CC0-1.0
Archived
2026-10-07T22:36:32.685Z
SHA-256 of the archived text
c06596623fa01df03bf1e0cf0587b399ab9698810b63765ecfda5ca2a5450062
Stable URL of this page
https://metraipolis.com/documento/dc_385a7b4c6918

How to cite

Traceprop: Training Data Attribution in a Single Pass — arXiv:2609.32380 — arXiv (en), https://arxiv.org/abs/2609.32380 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_385a7b4c6918 (Metraipolis archive dc_385a7b4c6918, sha256 c06596623fa01df03bf1e0cf0587b399ab9698810b63765ecfda5ca2a5450062)
BibTeX
@misc{dc385a7b4c6918,
  title = {Traceprop: Training Data Attribution in a Single Pass — arXiv:2609.32380},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.32380},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_385a7b4c6918; sha256 c06596623fa01df03bf1e0cf0587b399ab9698810b63765ecfda5ca2a5450062},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.32380. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Data attribution tools used in practice, TRAK, LoGRA/LogIX, and EK-FAC, run after training: they recompute per-sample gradients in a separate pass over the training set, and curvature-aware variants need a further pass to estimate covariance. Traceprop records projected per-sample gradients and K-FAC covariance statistics inside the training backward pass itself. On Pythia-1B LoRA fine-tunes on an A100, this adds 2.6% to training time, against 10.7% for LogIX's best inline configuration, random-init (4.1x lower, one-sided Mann-Whitney p = 9e-5, n = 10 per arm); at Pythia-6.9B the numbers are 11.3% and 27.0% (p = 0.004). LogIX's default configuration, PCA-init, is both slower and lower quality than random-init, so we compare against random-init throughout. On a small transformer where LDS is measurable, Traceprop matches LogIX's best configuration: pooled LDS difference +0.0022, 95% CI [-0.0038, +0.0075]. Two things do not work: at Pythia-160M/SST-2, every method is indistinguishable from a low noise ceiling, and on planted-backdoor and mislabel detection, gradient attribution does not beat gradient norm or representation similarity. The contribution here is systems, not a new estimator: LogIX's attribution quality, in one pass instead of two.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-29 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2609.32380 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T22:14:27.672Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).