Metraipolis › archive › dc_37caacb3a79a
Drift Calibration in Geometric Eye Tracking Systems — arXiv:2608.29739
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.29739
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T09:59:05.625Z
- SHA-256 of the archived text
89a213c4a2a648d9185e955c75ef5750dae8de5ff2b0720faabf893a01390ca6- Stable URL of this page
https://metraipolis.com/documento/dc_37caacb3a79a
How to cite
Drift Calibration in Geometric Eye Tracking Systems — arXiv:2608.29739 — arXiv (en), https://arxiv.org/abs/2608.29739 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_37caacb3a79a (Metraipolis archive dc_37caacb3a79a, sha256 89a213c4a2a648d9185e955c75ef5750dae8de5ff2b0720faabf893a01390ca6)
BibTeX
@misc{dc37caacb3a79a,
title = {Drift Calibration in Geometric Eye Tracking Systems — arXiv:2608.29739},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.29739},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_37caacb3a79a; sha256 89a213c4a2a648d9185e955c75ef5750dae8de5ff2b0720faabf893a01390ca6},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.29739. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Geometric eye trackers can provide the spatial accuracy required for gaze-based interaction and multimodal studies, but their measurements remain sensitive to residual session-specific calibration error. Research on correcting this error is difficult to compare because methods are typically evaluated with different devices, target layouts, and error definitions. We present a calibration-focused dataset containing 163 trials from 12 participants, with separate 18-point fitting and 32-point test grids, and use it to evaluate global, local, and composite correction functions under a common spatial-extrapolation protocol. We further introduce a lightweight neural refiner that combines ranked predictions from complementary calibrators. On this controlled dataset, post-vendor correction reduces the mean angular error from $1.53^\circ$ to $1.03^\circ$ with the strongest classical composite and to $0.96^\circ$ with the refiner. In a closed-loop gaze task, lower residual error is associated with higher performance across four online correction conditions. These results provide a reproducible data-quality benchmark for using gaze as a behavioral signal in interactive modeling. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2608.29739 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T09:28:48.061Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).