Metraipolis › archive › dc_36cc3e28edb0
Enhanced surface plasmon resonance biosensor with graphene-black phosphorus heterostructure for ultra-high sensitivity refractive index detection with machine… — Europe PMC PMID:41202096
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/41202096
- DOI
- 10.1371/journal.pone.0332356
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-06T08:50:40.012Z
- SHA-256 of the archived text
4fe6ce6b0aee86a5d834ffb08f24825e000e11a93e151ee3a61f5b2ce2462c9d- Stable URL of this page
https://metraipolis.com/documento/dc_36cc3e28edb0
How to cite
Enhanced surface plasmon resonance biosensor with graphene-black phosphorus heterostructure for ultra-high sensitivity refractive index detection with machine… — Europe PMC PMID:41202096 — Europe PMC (en), https://europepmc.org/article/MED/41202096 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_36cc3e28edb0 (Metraipolis archive dc_36cc3e28edb0, sha256 4fe6ce6b0aee86a5d834ffb08f24825e000e11a93e151ee3a61f5b2ce2462c9d)
BibTeX
@misc{dc36cc3e28edb0,
title = {Enhanced surface plasmon resonance biosensor with graphene-black phosphorus heterostructure for ultra-high sensitivity refractive index detection with machine… — Europe PMC PMID:41202096},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/41202096},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_36cc3e28edb0; sha256 4fe6ce6b0aee86a5d834ffb08f24825e000e11a93e151ee3a61f5b2ce2462c9d},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/41202096. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This study reports a five-layer surface plasmon resonance biosensor architecture comprising a BK7 glass substrate, silver plasmonic film, monolayer graphene, black phosphorus dielectric, and analyte region, engineered for high-precision detection of low refractive index media. The graphene-black phosphorus heterostructure synergistically exploits the exceptionally high surface-to-volume ratio of graphene and the anisotropic optical response of black phosphorus, enabling pronounced electromagnetic field confinement at the sensor interface. In particular, the detection procedure is mainly dependent on the emergence of the angular surface plasmon resonance based on the optimum values of the different geometrical and structural parameters. Therefore, the electromagnetic optimization using COMSOL Multiphysics was performed by varying the silver thickness, graphene thickness and black phosphorus thickness over an analyte index range of 1.29-1.38 RIU. The optimized configuration achieved a maximum sensitivity of 300°/RIU at n = 1.35 RIU, with a figure of merit of 45.455 RIU-1 and a detection limit of 0.018 RIU, surpassing previously reported architectures. Furthermore, predictive validation employing K-nearest neighbours regression demonstrated excellent reliability, yielding R² values between 92-100% and mean absolute errors of 0.005-0.012 RIU. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2025 (prima pubblicazione 2025-11-07). Identificativi: PMID 41202096 · PMCID PMC12594348 · DOI 10.1371/journal.pone.0332356. Descrittori MeSH principali: Refractometry; Surface Plasmon Resonance; Biosensing Techniques; Machine Learning. Pagina: https://europepmc.org/article/MED/41202096 — https://doi.org/10.1371/journal.pone.0332356. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-10-06T08:20:26.655Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.