Metraipolis › archive › dc_363fc4014b5b
Embedding Single-Phase Grid-Forming Inverters in Three-Phase Unbalanced Power Flow — arXiv:2609.03154
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.03154
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T03:02:41.830Z
- SHA-256 of the archived text
963f0bde987432aa6aa6d5980a7c5d3a960a5db9728bcda2bb2092bb9a6065c6- Stable URL of this page
https://metraipolis.com/documento/dc_363fc4014b5b
How to cite
Embedding Single-Phase Grid-Forming Inverters in Three-Phase Unbalanced Power Flow — arXiv:2609.03154 — arXiv (en), https://arxiv.org/abs/2609.03154 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_363fc4014b5b (Metraipolis archive dc_363fc4014b5b, sha256 963f0bde987432aa6aa6d5980a7c5d3a960a5db9728bcda2bb2092bb9a6065c6)
BibTeX
@misc{dc363fc4014b5b,
title = {Embedding Single-Phase Grid-Forming Inverters in Three-Phase Unbalanced Power Flow — arXiv:2609.03154},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.03154},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_363fc4014b5b; sha256 963f0bde987432aa6aa6d5980a7c5d3a960a5db9728bcda2bb2092bb9a6065c6},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.03154. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This letter introduces Grid-Forming Three-Phase Power Flow (GFM-3PF), an augmented Newton power flow framework for modeling single-phase grid-forming inverters (GFMs) in three-phase unbalanced networks. The contributions of this work are threefold: 1) developing a two-stage solution strategy based on positive-sequence initialization followed by three-phase phase-domain lifting for robust large-scale computation; 2) incorporating phase-domain unbalanced network modeling with controlled mutual coupling together with phase-dependent, frequency-sensitive load representation; and 3) embedding a single-phase GFM bus model directly into the three-phase unbalanced Newton power flow equations through a common droop-governed frequency state. GFM-3PF is validated on 3-bus, 33-bus, and 118-bus test systems, demonstrating its accuracy, robustness, and scalability. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-04 in cs.ET). Categorie arXiv: Emerging Technologies (cs.ET). Pagina del lavoro: https://arxiv.org/abs/2609.03154 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T02:48:28.927Z dalla pagina https://arxiv.org/catchup/cs.ET/2026-09-04?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).