Metraipolis › archive › dc_35582d9016a1

DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion — arXiv:2611.04405

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.04405
License (as archived)
CC0-1.0
Archived
2026-11-04T12:56:22.787Z
SHA-256 of the archived text
b238466d04097a9f11f6e13a7ee4366d8b76c94e7a1fa745042a1284c1be360b
Stable URL of this page
https://metraipolis.com/documento/dc_35582d9016a1

How to cite

DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion — arXiv:2611.04405 — arXiv (en), https://arxiv.org/abs/2611.04405 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_35582d9016a1 (Metraipolis archive dc_35582d9016a1, sha256 b238466d04097a9f11f6e13a7ee4366d8b76c94e7a1fa745042a1284c1be360b)
BibTeX
@misc{dc35582d9016a1,
  title = {DR-LiteNet: A Lightweight Explainable Hybrid CNN Framework for Imbalanced Diabetic Retinopathy Grading via Adaptive SMOTE Fusion — arXiv:2611.04405},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.04405},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_35582d9016a1; sha256 b238466d04097a9f11f6e13a7ee4366d8b76c94e7a1fa745042a1284c1be360b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.04405. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Automated diabetic retinopathy (DR) grading from colour fundus photographs is held back by two compounding challenges: severe class imbalance across five severity grades and the heavy computational cost of large scale architectures in resource constrained clinical settings. We introduce DR-LiteNet, a dual branch hybrid convolutional neural network that tackles both problems at once. The CNN branch extracts 1,280 dimensional deep features through EfficientNetB0, while the handcrafted (HC) branch produces a compact 51 dimensional lesion descriptor capturing vessel density, exudate intensity, texture entropy, and HSV colour histograms. Concatenating both branches yields a 1,331-d hybrid embedding, on which Adaptive SMOTE (ADASYN) is applied during training to synthesise minority class feature vectors, correcting distributional skew without touching the image space. A two phase training protocol first warms up the classification head on balanced features, then fine tunes the full network end to end. Grad CAM saliency maps deliver post-hoc clinical explainability. Tested on APTOS 2019 under five fold stratified cross validation, DR-LiteNet reaches 88.77% +/- 0.61 accuracy, a quadratic weighted kappa (QWK) of 0.884 +/- 0.010, and a macro F1 of 0.792 +/- 0.008 with only 4.69 M parameters beating ResNet50 (23.5 M) by DeltaQWK = 0.022 while staying practical on a single Google Colab T4 GPU. The source code of this project is available at: this https URL .

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2611.04405 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-04T12:33:47.138Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).