Metraipolis › archive › dc_351610869b71

MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision — arXiv:2609.08148

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.08148
License (as archived)
CC0-1.0
Archived
2026-10-16T15:12:05.336Z
SHA-256 of the archived text
8236ef5d39fd9c7d6990823d297fb6a3917db2c82feaf2c528f3349af7a02bae
Stable URL of this page
https://metraipolis.com/documento/dc_351610869b71

How to cite

MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision — arXiv:2609.08148 — arXiv (en), https://arxiv.org/abs/2609.08148 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_351610869b71 (Metraipolis archive dc_351610869b71, sha256 8236ef5d39fd9c7d6990823d297fb6a3917db2c82feaf2c528f3349af7a02bae)
BibTeX
@misc{dc351610869b71,
  title = {MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision — arXiv:2609.08148},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.08148},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_351610869b71; sha256 8236ef5d39fd9c7d6990823d297fb6a3917db2c82feaf2c528f3349af7a02bae},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.08148. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. We evaluate three weak-mask generators -- LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning -- and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.928 Dice and 3.80mm HD95 with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-09 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.08148 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T14:49:57.279Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).