Metraipolis › archive › dc_34ecc616363d
Toward a New Primary Standardization of Radionuclide Massic Activity Using Microcalorimetry and Quantitative Milligram-Scale Samples — Europe PMC PMID:38469443
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/38469443
- DOI
- 10.6028/jres.126.048
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-06T11:37:43.473Z
- SHA-256 of the archived text
b6ab7b2a4dcbc19e18883dad9df7049c2b1af96fa0162ac2e6f9b365be02c190- Stable URL of this page
https://metraipolis.com/documento/dc_34ecc616363d
How to cite
Toward a New Primary Standardization of Radionuclide Massic Activity Using Microcalorimetry and Quantitative Milligram-Scale Samples — Europe PMC PMID:38469443 — Europe PMC (en), https://europepmc.org/article/MED/38469443 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_34ecc616363d (Metraipolis archive dc_34ecc616363d, sha256 b6ab7b2a4dcbc19e18883dad9df7049c2b1af96fa0162ac2e6f9b365be02c190)
BibTeX
@misc{dc34ecc616363d,
title = {Toward a New Primary Standardization of Radionuclide Massic Activity Using Microcalorimetry and Quantitative Milligram-Scale Samples — Europe PMC PMID:38469443},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/38469443},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_34ecc616363d; sha256 b6ab7b2a4dcbc19e18883dad9df7049c2b1af96fa0162ac2e6f9b365be02c190},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/38469443. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We present a new paradigm for the primary standardization of radionuclide activity per mass of solution (Bq/g). Two key enabling capabilities are 4π decay-energy spectrometry using chip-scale sub-Kelvin microcalorimeters and direct realization of mass by gravimetric inkjet dispensing using an electrostatic force balance. In contrast to traditional traceability, which typically relies on chemical separation of single-radionuclide samples, 4π integral counting, and additional spectrometry methods to verify purity, the system described here has both 4π counting efficiency and spectroscopic resolution sufficient to identify multiple radionuclides in the same sample at once. This enables primary standardization of activity concentrations of mixed-radionuclide samples. A major benefit of this capability, beyond metrology, is in assay of environmental and forensics samples, for which the quantification of multiplenuclide samples can be achieved where presently inhibited by interferences. This can be achieved without the need for chemical separations or efficiency tracers, thereby vastly reducing time, radioactive waste, and resulting measurement uncertainty. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: Journal of research of the National Institute of Standards and Technology, 2021 (prima pubblicazione 2021-01-01). Identificativi: PMID 38469443 · PMCID PMC10112850 · DOI 10.6028/jres.126.048. Parole chiave degli autori: Beta; Alpha; Microcalorimeter; Radioactivity; Radionuclide Metrology; Cryogenic Detectors; Mass Metrology; Transition Edge Sensor. Pagina: https://europepmc.org/article/MED/38469443 — https://doi.org/10.6028/jres.126.048. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-06T11:34:19.902Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.