Metraipolis › archive › dc_347bd22cad23
Droop-Aware Foundation Model Power Flow — arXiv:2609.23723
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.23723
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T22:41:54.979Z
- SHA-256 of the archived text
9e233cd5fbcf0fb0da12aeb03296187d66e0a90f87d2ea183d0f76573008be63- Stable URL of this page
https://metraipolis.com/documento/dc_347bd22cad23
How to cite
Droop-Aware Foundation Model Power Flow — arXiv:2609.23723 — arXiv (en), https://arxiv.org/abs/2609.23723 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_347bd22cad23 (Metraipolis archive dc_347bd22cad23, sha256 9e233cd5fbcf0fb0da12aeb03296187d66e0a90f87d2ea183d0f76573008be63)
BibTeX
@misc{dc347bd22cad23,
title = {Droop-Aware Foundation Model Power Flow — arXiv:2609.23723},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.23723},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_347bd22cad23; sha256 9e233cd5fbcf0fb0da12aeb03296187d66e0a90f87d2ea183d0f76573008be63},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.23723. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This paper develops a droop-aware extension of the GridFM power systems foundation model, embedding droop gains and frequency/voltage deadband parameters as per-bus node features to enable control-aware AC power-flow analysis. Existing power-flow datasets encode only static electrical features, conflating operating points from qualitatively different control regimes; this work resolves that gap by exposing droop and deadband parameters as structured node features, with deadband discontinuities handled through a smooth tanh approximation that preserves solver differentiability. A transformer-based graph neural network is pre-trained on masked reconstruction and fine-tuned on the resulting control-aware datasets. The framework is validated against PSCAD electromagnetic-transient simulations on a two-bus system (0.11% maximum steady-state error) and cross-validated against an independent PyPower droop solver on the IEEE 24-bus RTS. On the 24-bus system the surrogate attains R2 = 0.9996 for active generation and 0.0015 p.u. voltage-magnitude RMSE; scalability is confirmed on the IEEE 300-bus system (0.0036 p.u. RMSE, R2 = 0.9841 for voltage magnitude across 299,700 predictions). A three-mode control study further shows that the deadband widens the control-error distribution while leaving total droop compensation unchanged, establishing deadband width as an actionable node-level design feature. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-22 in cs.ET). Categorie arXiv: Emerging Technologies (cs.ET). Pagina del lavoro: https://arxiv.org/abs/2609.23723 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T22:25:18.765Z dalla pagina https://arxiv.org/catchup/cs.ET/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).