Metraipolis › archive › dc_34629f60a25e

The NIST Quantitative Infrared Database — Europe PMC PMC4877123

Source
Europe PMC (en)
Original
https://europepmc.org/article/PMC/PMC4877123
License (as archived)
CC0-1.0
Archived
2026-10-08T13:42:39.267Z
SHA-256 of the archived text
e927da7f5e2122b6c5130b00d8e98eafdffdfa7d22ffb211eebfeb71153e8271
Stable URL of this page
https://metraipolis.com/documento/dc_34629f60a25e

How to cite

The NIST Quantitative Infrared Database — Europe PMC PMC4877123 — Europe PMC (en), https://europepmc.org/article/PMC/PMC4877123 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_34629f60a25e (Metraipolis archive dc_34629f60a25e, sha256 e927da7f5e2122b6c5130b00d8e98eafdffdfa7d22ffb211eebfeb71153e8271)
BibTeX
@misc{dc34629f60a25e,
  title = {The NIST Quantitative Infrared Database — Europe PMC PMC4877123},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/PMC/PMC4877123},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_34629f60a25e; sha256 e927da7f5e2122b6c5130b00d8e98eafdffdfa7d22ffb211eebfeb71153e8271},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/PMC/PMC4877123. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

With the recent developments in Fourier transform infrared (FTIR) spectrometers it is becoming more feasible to place these instruments in field environments. As a result, there has been enormous increase in the use of FTIR techniques for a variety of qualitative and quantitative chemical measurements. These methods offer the possibility of fully automated real-time quantitation of many analytes; therefore FTIR has great potential as an analytical tool. Recently, the U.S. Environmental Protection Agency (U.S.EPA) has developed protocol methods for emissions monitoring using both extractive and open-path FTIR measurements. Depending upon the analyte, the experimental conditions and the analyte matrix, approximately 100 of the hazardous air pollutants (HAPs) listed in the 1990 U.S.EPA Clean Air Act amendment (CAAA) can be measured. The National Institute of Standards and Technology (NIST) has initiated a program to provide quality-assured infrared absorption coefficient data based on NIST prepared primary gas standards. Currently, absorption coefficient data has been acquired for approximately 20 of the HAPs. For each compound, the absorption coefficient spectrum was calculated using nine transmittance spectra at 0.12 cm−1 resolution and the Beer’s law relationship. The uncertainties in the absorption coefficient data were estimated from the linear regressions of the transmittance data and considerations of other error sources such as the nonlinear detector response. For absorption coefficient values greater than 1 × 10−4 μmol/mol)−1 m−1 the average relative expanded uncertainty is 2.2 %. This quantitative infrared database is currently an ongoing project at NIST. Additional spectra will be added to the database as they are acquired. Our current plans include continued data acquisition of the compounds listed in the CAAA, as well as the compounds that contribute to global warming and ozone depletion.

Tema degli esploratori: fiducia digitale e crittografia (ricerca Europe PMC «digital signature», solo open access).
Pubblicazione: Journal of research of the National Institute of Standards and Technology, 1999 (prima pubblicazione 1999-01-01).
Identificativi: PMCID PMC4877123.
Parole chiave degli autori: Database; Air pollutants; Gas Standards; Infrared Spectrometer.
Pagina: https://europepmc.org/article/PMC/PMC4877123. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-08T13:17:26.842Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.