Metraipolis › archive › dc_33ba7d4b5890

Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions — arXiv:2610.21115

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.21115
License (as archived)
CC0-1.0
Archived
2026-10-16T10:56:22.487Z
SHA-256 of the archived text
22ffaa9b727014decd2608f8571384124d1d71100a4f17dfff93c301aac3857c
Stable URL of this page
https://metraipolis.com/documento/dc_33ba7d4b5890

How to cite

Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions — arXiv:2610.21115 — arXiv (en), https://arxiv.org/abs/2610.21115 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_33ba7d4b5890 (Metraipolis archive dc_33ba7d4b5890, sha256 22ffaa9b727014decd2608f8571384124d1d71100a4f17dfff93c301aac3857c)
BibTeX
@misc{dc33ba7d4b5890,
  title = {Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions — arXiv:2610.21115},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.21115},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_33ba7d4b5890; sha256 22ffaa9b727014decd2608f8571384124d1d71100a4f17dfff93c301aac3857c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.21115. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Histopathology classifiers must transfer across acquisition sites while exposing evidence that can be checked independently. Evidence Field couples learned image measurements and spatial classification with a native covering-program record. We evaluate this architecture on all 455,954 released CAMELYON17-WILDS patches, using patient-separated source partitions and two held-out hospital centres. Eighteen from-scratch fits compare four Evidence Field objectives with residual convolutional and compact vision-transformer classifiers. Checkpoints, temperatures and review thresholds are selected using source validation. The source-selected paired-cross-entropy ensemble achieves areas under the receiver operating characteristic curve of 0.9356 and 0.9453, with accuracies of 84.46% and 86.77% at the two held-out centres. Corresponding convolutional values are 0.7352 and 0.7656, and transformer values are 0.8502 and 0.7924. Evidence Field has 10,550 trainable parameters per member and additionally returns selected covers, signed region and interaction terms, contextual dependencies and independently reconstructible predictions. Patient-cluster intervals, calibration, source-fixed review policies and recorded training resources characterize the results. A 340-image, three-member audit reconstructs probability mixtures and 6,120 class programs under three rigid views. The evaluation supports cross-centre discrimination and reproducible computation for these implemented models; unequal family tuning, previously examined public targets and limited patient groups constrain broader interpretation.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.IV, nuovi lavori del giorno).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2610.21115 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T09:02:37.210Z dalla pagina https://arxiv.org/list/eess.IV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).