Metraipolis › archive › dc_338d058628a9

Streaming P300 Acquisition and Statistical Signal Validation Across Five EEG Platforms: A Hardware-Agnostic BrainFlow/LSL Pipeline — arXiv:2609.10047

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.10047
License (as archived)
CC0-1.0
Archived
2026-10-16T07:55:04.211Z
SHA-256 of the archived text
6559b25c942b8df6e0b31ca821496db9153bca17ae7e15a3731d3ca31bcbecc0
Stable URL of this page
https://metraipolis.com/documento/dc_338d058628a9

How to cite

Streaming P300 Acquisition and Statistical Signal Validation Across Five EEG Platforms: A Hardware-Agnostic BrainFlow/LSL Pipeline — arXiv:2609.10047 — arXiv (en), https://arxiv.org/abs/2609.10047 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_338d058628a9 (Metraipolis archive dc_338d058628a9, sha256 6559b25c942b8df6e0b31ca821496db9153bca17ae7e15a3731d3ca31bcbecc0)
BibTeX
@misc{dc338d058628a9,
  title = {Streaming P300 Acquisition and Statistical Signal Validation Across Five EEG Platforms: A Hardware-Agnostic BrainFlow/LSL Pipeline — arXiv:2609.10047},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.10047},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_338d058628a9; sha256 6559b25c942b8df6e0b31ca821496db9153bca17ae7e15a3731d3ca31bcbecc0},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10047. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

P300 spellers offer people with severe motor impairment, such as ALS, an effective communication channel and remain one of the most established surgery-free alternatives to intracortical interfaces. Advanced language models have made spellers faster and more robust, yet the hardware beneath them is under-studied. We present a hardware-agnostic, real-time P300 acquisition pipeline built on BrainFlow and Lab Streaming Layer (LSL) that runs unchanged across consumer- and research-grade EEG headsets, with permutation tests of signal separability. Using a standard 6 x 6 row/column paradigm, we piloted five configurations: a custom dry system, a custom wet/gel system, Emotiv Flex, Emotiv EPOC X, and Muse 2. The custom systems and EPOC X showed weak or inconsistent signal separability, Muse 2 had the highest acquisition reliability despite limited centro-parietal coverage, and Flex showed the most promising signal. In 20 further Flex sessions varying subject, timing, and phrase length (131 target characters), a peak-amplitude permutation test and a cross-validated xDAWN decoder both detected a significant target response under two channel-exclusion policies, with decoder AUC reaching about 0.72 after 15 repetitions. Character accuracy depended heavily on evaluation methodology: in-sample majority voting reached 94.7%, whereas character-held-out accuracy was 31.3% with evidence accumulated across repetitions, about three times that of held-out majority voting. These analyses indicate that Flex captured a detectable, if still weak, P300 under the studied conditions, while broader participant-level validation and improved decoding remain necessary.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-10 in cs.HC).
Categorie arXiv: Human-Computer Interaction (cs.HC).
Pagina del lavoro: https://arxiv.org/abs/2609.10047 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T07:37:55.645Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-09-10?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).