Metraipolis › archive › dc_3341e134767f

Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot — arXiv:2608.28371

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.28371
License (as archived)
CC0-1.0
Archived
2026-10-17T10:48:17.133Z
SHA-256 of the archived text
cb03493fa256bba105708112fe70621cf7dbee52facd16bd33e9c650b07ff058
Stable URL of this page
https://metraipolis.com/documento/dc_3341e134767f

How to cite

Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot — arXiv:2608.28371 — arXiv (en), https://arxiv.org/abs/2608.28371 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3341e134767f (Metraipolis archive dc_3341e134767f, sha256 cb03493fa256bba105708112fe70621cf7dbee52facd16bd33e9c650b07ff058)
BibTeX
@misc{dc3341e134767f,
  title = {Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot — arXiv:2608.28371},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.28371},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3341e134767f; sha256 cb03493fa256bba105708112fe70621cf7dbee52facd16bd33e9c650b07ff058},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28371. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Real-time musculoskeletal (MSK) surrogates could support personalized rehabilitation for children with cerebral palsy (CP), but their credibility depends on subject-wise evaluation, low inference latency, and calibrated uncertainty. We develop a subject-conditioned causal neural surrogate using OpenSim-derived static parameters, temporal joint kinematics, true muscle capacities, and training-only perturbations. On a real pediatric CP gait dataset comprising nine children, we use leave-one-subject-out validation on six development subjects and evaluate a frozen configuration once on three locked test subjects. The surrogate accurately reproduces musculotendon lengths (R-square = 0.92 in development validation and approximately 0.95 on locked subjects; nRMSE < 8%) while requiring only sub-millisecond to few-millisecond neural inference, well below a 100 ms interactive-rehabilitation target. In contrast, direct muscle-force estimation remains unstable at this small, heterogeneous scale: pooled metrics can overstate within-subject, per-muscle accuracy. A Monte Carlo credibility pilot further shows that propagating only +/-5% anthropometry and muscle-capacity variation produces severely overconfident nominal 90% intervals (approximately 4% force coverage and below 1% MT-length coverage). These results establish a leakage-free evaluation and credibility framework for pediatric MSK surrogates, while identifying force modeling and epistemic uncertainty as the central next challenges for clinically credible digital twins.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-31 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2608.28371 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T10:33:42.525Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-31?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).