Metraipolis › archive › dc_31abb18a96d2
Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations — arXiv:2609.04439
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.04439
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T23:33:20.424Z
- SHA-256 of the archived text
0443ea91a196916c9217ba572b31b4caa62a21bf62cb665098b4a1fed0448b07- Stable URL of this page
https://metraipolis.com/documento/dc_31abb18a96d2
How to cite
Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations — arXiv:2609.04439 — arXiv (en), https://arxiv.org/abs/2609.04439 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_31abb18a96d2 (Metraipolis archive dc_31abb18a96d2, sha256 0443ea91a196916c9217ba572b31b4caa62a21bf62cb665098b4a1fed0448b07)
BibTeX
@misc{dc31abb18a96d2,
title = {Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations — arXiv:2609.04439},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.04439},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_31abb18a96d2; sha256 0443ea91a196916c9217ba572b31b4caa62a21bf62cb665098b4a1fed0448b07},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.04439. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-efficient hybrid 4D kernel to capture temporal context and sparse 4D labels derived from existing 2D expert contours and centerlines, thereby avoiding the need for dense 4D annotations. Training comprised 268 scans from 8 centers and 2 vendors, with evaluation on an internal test set (32 scans) and an external post-contrast set (30 scans; different site, protocol, and annotator), compared against frame-wise 3D networks and two semi-automatic references. Against time-resolved annotations, the 4D U-Net achieved Dice scores of 0.927 (internal) and 0.911 (external), versus 0.919/0.847 for the 3D U-Net, 0.893 for static PC-MRA, and 0.808 for registration-based propagation; differences were small in systole but pronounced in diastole. Agreement with expert contours for peak velocity, net flow, axial and circumferential wall shear stress, and diameters was excellent (ICC >=0.954 internal, >=0.980 external), while semi-automatic references performed worse. The method thus provides reproducible, time-resolved aortic segmentation for automated hemodynamic analysis and generalizes across multicenter, multivendor, and independent post-contrast data. The model is publicly available. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-07 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.04439 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T23:16:11.384Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).