Metraipolis › archive › dc_30ec256a09f5
Supervised Cross-Modal Feature Alignment for Zero-Wearable Freezing of Gait Detection in Parkinsonism — arXiv:2609.08317
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.08317
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T15:12:12.944Z
- SHA-256 of the archived text
8c942098292bfd50422fce39c613217f0d6e14c3df59193caf13ea92b421049f- Stable URL of this page
https://metraipolis.com/documento/dc_30ec256a09f5
How to cite
Supervised Cross-Modal Feature Alignment for Zero-Wearable Freezing of Gait Detection in Parkinsonism — arXiv:2609.08317 — arXiv (en), https://arxiv.org/abs/2609.08317 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_30ec256a09f5 (Metraipolis archive dc_30ec256a09f5, sha256 8c942098292bfd50422fce39c613217f0d6e14c3df59193caf13ea92b421049f)
BibTeX
@misc{dc30ec256a09f5,
title = {Supervised Cross-Modal Feature Alignment for Zero-Wearable Freezing of Gait Detection in Parkinsonism — arXiv:2609.08317},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.08317},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_30ec256a09f5; sha256 8c942098292bfd50422fce39c613217f0d6e14c3df59193caf13ea92b421049f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.08317. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Objective assessment of Freezing of Gait (FoG) in Parkinson's disease (PD) relies predominantly on wearable Inertial Measurement Units (IMUs). While IMUs provide optimal kinematic precision, mandatory sensor attachment restricts continuous clinical deployment. Conversely, unobtrusive vision-based alternatives suffer substantial classification errors during turning-in-place tasks, where geometric self-occlusion degrades deterministic skeletal coordinates and obscures the high-frequency precursors required for FoG detection. To resolve these physical observation limits, we propose a supervised cross-modal subspace distillation framework. During optimisation, pre-trained kinematic data from IMU sensors and contextual clinical metadata act as oracles to guide a deployable visual architecture. By incorporating joint velocity and acceleration derivatives, utilising a confidence-based gating mechanism, the visual model mitigates some of the tracking errors during occlusion events. Empirical evaluations confirm this latent alignment transfers the predictive fidelity of hardware sensors directly into the visual representation, yielding $85.5\%$ accuracy, and $82.4\%$ balanced accuracy. All the while maintaining a vision only model at inference. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-09 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.08317 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T14:49:57.307Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).