Metraipolis › archive › dc_30d25ebc8060

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI — arXiv:2611.05169

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.05169
License (as archived)
CC0-1.0
Archived
2026-11-04T19:14:23.801Z
SHA-256 of the archived text
1af0445edbfd259952649d46db0224b04410bbd40368ab35711c5573024dc215
Stable URL of this page
https://metraipolis.com/documento/dc_30d25ebc8060

How to cite

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI — arXiv:2611.05169 — arXiv (en), https://arxiv.org/abs/2611.05169 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_30d25ebc8060 (Metraipolis archive dc_30d25ebc8060, sha256 1af0445edbfd259952649d46db0224b04410bbd40368ab35711c5573024dc215)
BibTeX
@misc{dc30d25ebc8060,
  title = {Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI — arXiv:2611.05169},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.05169},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_30d25ebc8060; sha256 1af0445edbfd259952649d46db0224b04410bbd40368ab35711c5573024dc215},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.05169. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.IV, nuovi lavori del giorno).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2611.05169 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-04T18:49:07.636Z dalla pagina https://arxiv.org/list/eess.IV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).