Metraipolis › archive › dc_30487e7844f5
End-to-End Battery Dispatch with Exact Rainflow Degradation via Mixed-Integer Differentiable Predictive Control — arXiv:2609.12968
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.12968
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T04:27:55.248Z
- SHA-256 of the archived text
68b09f0164e8f3cd4a0c2ef0cca99abe622679d43db797c6e4d635fa79759bf1- Stable URL of this page
https://metraipolis.com/documento/dc_30487e7844f5
How to cite
End-to-End Battery Dispatch with Exact Rainflow Degradation via Mixed-Integer Differentiable Predictive Control — arXiv:2609.12968 — arXiv (en), https://arxiv.org/abs/2609.12968 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_30487e7844f5 (Metraipolis archive dc_30487e7844f5, sha256 68b09f0164e8f3cd4a0c2ef0cca99abe622679d43db797c6e4d635fa79759bf1)
BibTeX
@misc{dc30487e7844f5,
title = {End-to-End Battery Dispatch with Exact Rainflow Degradation via Mixed-Integer Differentiable Predictive Control — arXiv:2609.12968},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.12968},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_30487e7844f5; sha256 68b09f0164e8f3cd4a0c2ef0cca99abe622679d43db797c6e4d635fa79759bf1},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.12968. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Optimal dispatch of battery energy storage systems requires balancing energy arbitrage against cycle-induced degradation, which is accurately quantified through rainflow cycle counting. However, rainflow's combinatorial, nondifferentiable algorithm is incompatible with both convex optimization and gradient-based neural network training. We present a self-supervised mixed-integer differentiable predictive control framework that trains neural policies directly on exact rainflow degradation through a novel differentiable rainflow layer combining exact gradients at state-of-charge extrema with dense proxy gradients on incremental changes, enabling stable end-to-end training while preserving true degradation physics. A mixed-integer differentiable architecture enforces power balance, dynamics, and mode exclusivity, with a safety filter guaranteeing constraint satisfaction. We evaluate the framework on 3,650 real battery-day scenarios (a 10-battery fleet over 365 days) spanning three utility regions (SDG&E California, Xcel Energy Colorado, APS Arizona) with diverse time-of-use pricing structures. A single-battery trained policy achieves a 0.35% performance gap on its training distribution with over 200x speedup, while fleet-wide training generalizes across all households and utility regions, achieving a 3.33% performance gap with 564x computational speedup (62 seconds vs. 9.7 hours) and 100% feasibility. The millisecond-scale inference reduces computation by over two orders of magnitude compared to mixed-integer solvers, enabling practical deployment at scale. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-14 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.12968 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T04:21:20.144Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-14?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).