Metraipolis › archive › dc_3016d4fba161

Posterior Geometry and Identifiability in Multi-Response Bayesian Calibration — arXiv:2608.31047

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.31047
License (as archived)
CC0-1.0
Archived
2026-10-17T09:00:10.918Z
SHA-256 of the archived text
347a7d1fc4a5d94cba785565fae28fcdab8bac197295eb8b4a04a87afbe7267f
Stable URL of this page
https://metraipolis.com/documento/dc_3016d4fba161

How to cite

Posterior Geometry and Identifiability in Multi-Response Bayesian Calibration — arXiv:2608.31047 — arXiv (en), https://arxiv.org/abs/2608.31047 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_3016d4fba161 (Metraipolis archive dc_3016d4fba161, sha256 347a7d1fc4a5d94cba785565fae28fcdab8bac197295eb8b4a04a87afbe7267f)
BibTeX
@misc{dc3016d4fba161,
  title = {Posterior Geometry and Identifiability in Multi-Response Bayesian Calibration — arXiv:2608.31047},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.31047},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_3016d4fba161; sha256 347a7d1fc4a5d94cba785565fae28fcdab8bac197295eb8b4a04a87afbe7267f},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.31047. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Calibration under model misspecification is inherently ill-posed because calibration parameters and structural discrepancy are statistically confounded without additional assumptions. Bayesian formulations address this ambiguity through prior and covariance modeling choices, including multi-response observations and cross-source alignment. However, how these choices, together with output-dependent uncertainty, shape posterior geometry and practical parameter identifiability remains poorly understood. We present a latent-variable multi-response calibration model that combines empirical Bayes estimation of nuisance hyperparameters with a Fisher-information-based local Gaussian approximation of the calibration-parameter posterior. Closed-form expressions are derived for squared-exponential and Matérn covariance functions, revealing how multi-response correlations, latent alignment, and output-specific uncertainty influence local posterior geometry. Controlled numerical experiments show that additional responses provide complementary geometric constraints on calibration parameters, while noise modeling can improve uncertainty quantification by reducing overconfidence without necessarily improving parameter localization. A lithium-ion battery study further illustrates how the model distinguishes strongly from weakly constrained parameters. Together, these results establish expected-Fisher posterior geometry as a scalable diagnostic of local parameter identifiability in multi-response calibration.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in stat.ME).
Categorie arXiv: Methodology (stat.ME).
Pagina del lavoro: https://arxiv.org/abs/2608.31047 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T08:39:34.533Z dalla pagina https://arxiv.org/catchup/stat.ME/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).