Metraipolis › archive › dc_2fd886c0f7a8

Beat-Synchronous Tokenization for ECG Transformers — arXiv:2608.30367

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.30367
License (as archived)
CC0-1.0
Archived
2026-10-17T08:39:10.812Z
SHA-256 of the archived text
3d629ac8f9a3078005b9a215a7d47f39423260d27db1a96e3cd68188fcf9f1b7
Stable URL of this page
https://metraipolis.com/documento/dc_2fd886c0f7a8

How to cite

Beat-Synchronous Tokenization for ECG Transformers — arXiv:2608.30367 — arXiv (en), https://arxiv.org/abs/2608.30367 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2fd886c0f7a8 (Metraipolis archive dc_2fd886c0f7a8, sha256 3d629ac8f9a3078005b9a215a7d47f39423260d27db1a96e3cd68188fcf9f1b7)
BibTeX
@misc{dc2fd886c0f7a8,
  title = {Beat-Synchronous Tokenization for ECG Transformers — arXiv:2608.30367},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.30367},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2fd886c0f7a8; sha256 3d629ac8f9a3078005b9a215a7d47f39423260d27db1a96e3cd68188fcf9f1b7},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.30367. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R--R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-01 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG) ; Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2608.30367 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T08:13:26.811Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).