Metraipolis › archive › dc_2f3fa321a0a4
FD-AA: A Lightweight Focal-Diffuse And Attenuation-Aware Head for Incidental Abdominal Abnormality Detection in Chest CT — arXiv:2609.36189
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.36189
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T18:38:03.230Z
- SHA-256 of the archived text
d72282c47e744c4dc51b080bef79840ff556f66d6cf99ad156778dd3a7fd78e0- Stable URL of this page
https://metraipolis.com/documento/dc_2f3fa321a0a4
How to cite
FD-AA: A Lightweight Focal-Diffuse And Attenuation-Aware Head for Incidental Abdominal Abnormality Detection in Chest CT — arXiv:2609.36189 — arXiv (en), https://arxiv.org/abs/2609.36189 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2f3fa321a0a4 (Metraipolis archive dc_2f3fa321a0a4, sha256 d72282c47e744c4dc51b080bef79840ff556f66d6cf99ad156778dd3a7fd78e0)
BibTeX
@misc{dc2f3fa321a0a4,
title = {FD-AA: A Lightweight Focal-Diffuse And Attenuation-Aware Head for Incidental Abdominal Abnormality Detection in Chest CT — arXiv:2609.36189},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.36189},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2f3fa321a0a4; sha256 d72282c47e744c4dc51b080bef79840ff556f66d6cf99ad156778dd3a7fd78e0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.36189. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Routine chest CT captures upper-abdominal structures that may contain clinically relevant incidental abnormalities. Detecting these findings requires feature extraction from organs with different spatial extents and attenuation patterns. We propose FD-AA, a lightweight organ-aware classification head adaptable for frozen 3-D CT encoders. Within each organ, an attenuation-aware module preserves sparse focal evidence, while masked generalized-mean pooling captures diffuse anomaly patterns. In seven abdominal organs, FD-AA with Pillar-0 achieved state-of-the-art (SOTA) performance in both the CT-RATE test set (AUC = 0.798) and the external RAD-ChestCT dataset (AUC = 0.713). More specifically, FD-AA improved macro AUC/AP from 0.763/0.346 to 0.798/0.405 over direct classification using frozen Pillar-0 only (p = 0.034/0.016). Such performance gain generalizes across multiple frozen encoders (AUC improvement on MedicalNet +9.8%, CT-CLIP +14.7%, ResNet +3.7%), demonstrating the effectiveness of FD-AA across different feature representations. These results support the effectiveness of integrating focal-diffuse aggregation with explicit HU evidence for incidental abdominal abnormality detection. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-30 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.36189 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T18:04:24.682Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-30?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).