Metraipolis › archive › dc_2f27e2b45109
A 3D measurement workflow for assessing replication quality and tool degradation in moulded microfluidic channels — arXiv:2610.39046
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.39046
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-01T02:54:41.369Z
- SHA-256 of the archived text
76a068df5181818d5b2b579e4ce15f88d8ef96bb6830950210e964d9d2e43bac- Stable URL of this page
https://metraipolis.com/documento/dc_2f27e2b45109
How to cite
A 3D measurement workflow for assessing replication quality and tool degradation in moulded microfluidic channels — arXiv:2610.39046 — arXiv (en), https://arxiv.org/abs/2610.39046 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2f27e2b45109 (Metraipolis archive dc_2f27e2b45109, sha256 76a068df5181818d5b2b579e4ce15f88d8ef96bb6830950210e964d9d2e43bac)
BibTeX
@misc{dc2f27e2b45109,
title = {A 3D measurement workflow for assessing replication quality and tool degradation in moulded microfluidic channels — arXiv:2610.39046},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.39046},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2f27e2b45109; sha256 76a068df5181818d5b2b579e4ce15f88d8ef96bb6830950210e964d9d2e43bac},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39046. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Mould-based replication, such as injection moulding with 3D-printed inserts, needs a check of how faithfully microchannels are transferred from master to polymer replica. It is usually limited to a width or depth ratio from one cross-section, which misses the sidewall shape and depends on where the section is taken. We present a workflow that assesses the whole channel from 3D scans of master and replica, without sectioning. The scans are registered on a common grid, and each height map is converted into a map of local slope. The correlation of the two slope maps over the channel interior, RQ$_d$, is reported with the channel dimensions and height- and slope-error maps. These outputs separate a change of shape from a change of size and locate it. A user can thereby compare mould materials, detect tool wear, and tell whether a deviation arose before or during moulding. On synthetic channels with known degradation, RQ$_d$ fell steadily as the sidewalls were rounded, whereas the height correlation levelled off. For injection moulding with stereolithography-printed inserts in three resins, RQ$_d$ ranged from 0.17 to 0.91 over fifteen insert-to-part pairs. The height correlation placed the ten well-formed channels within 0.03. Over a twenty-shot run, one insert's RQ$_d$ fell from 0.90 to 0.72 as its sidewalls wore, while its height correlation stayed above 0.93. We developed open-source software that implements the workflow. Because the workflow needs only registered 3D scans of a master and its replica, it can in principle be applied to other mould-based processes. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv physics.data-an, nuovi lavori del giorno). Categorie arXiv: Applied Physics (physics.app-ph) ; Data Analysis, Statistics and Probability (physics.data-an). Pagina del lavoro: https://arxiv.org/abs/2610.39046 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-01T02:20:43.304Z dalla pagina https://arxiv.org/list/physics.data-an/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).