Metraipolis › archive › dc_2e50994b56cc

Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation — arXiv:2610.08510

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.08510
License (as archived)
CC0-1.0
Archived
2026-10-07T11:19:45.243Z
SHA-256 of the archived text
5bdd2120bda70d42ba3cdffeb7b73d3d2861be0169166680362a0bdef0da6067
Stable URL of this page
https://metraipolis.com/documento/dc_2e50994b56cc

How to cite

Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation — arXiv:2610.08510 — arXiv (en), https://arxiv.org/abs/2610.08510 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2e50994b56cc (Metraipolis archive dc_2e50994b56cc, sha256 5bdd2120bda70d42ba3cdffeb7b73d3d2861be0169166680362a0bdef0da6067)
BibTeX
@misc{dc2e50994b56cc,
  title = {Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation — arXiv:2610.08510},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.08510},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2e50994b56cc; sha256 5bdd2120bda70d42ba3cdffeb7b73d3d2861be0169166680362a0bdef0da6067},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.08510. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Paired translation between quasiperiodic physiological waveforms (i.e., recovering a target oscillatory signal from the source) is central to the interpretation of cardiovascular signals derived from wearables placed at different body locations. This source-to-target mapping in these problems carries inherent geometric structure: the phase wraps around the cycle and must be treated as a circular variable, the amplitude remains strictly positive, and the beat-to-beat alignment can drift unpredictably across cycles and subjects. While deep neural networks have been used for phase estimation and complex-valued signal modeling, prior work does not explicitly learn phase transport between paired signals. Consequently, neither endpoint-supervised regression nor the standard affine path used in flow matching accounts for this phase--amplitude structure. We introduce \emph{cylindrical geodesic flow matching} for paired cardiovascular waveform translation. We show that the standard affine path used in flow matching distorts intermediate amplitude and instantaneous frequency when interpolating between quasiperiodic signals; replacing it with a closed-form geodesic on the phase--amplitude cylinder eliminates these artifacts and converts each training pair into dense, geometry-consistent velocity supervision. On zero-shot photoplethysmography and limited-support seismocardiography adaptation benchmarks, our method consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction, reducing Hilbert Transform, $L_2$, and Dynamic Time Warping distance by up to ${\sim}15\%$ over the strongest competing baseline. These results suggest that bridge geometry is a critical inductive bias for flow matching on oscillatory signal translation.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno).
Categorie arXiv: Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2610.08510 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T11:15:24.616Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).