Metraipolis › archive › dc_2cfc90113154

Event-Based Estimation for Detrusor Pressure Using a Single Bladder Catheter Augmented with Abdominal Electromyography — arXiv:2609.20993

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.20993
License (as archived)
CC0-1.0
Archived
2026-10-10T03:12:00.063Z
SHA-256 of the archived text
c990009029df855fd6efdbc43fd991a9ce5ff3c274c871cb2fe2829c309bfca9
Stable URL of this page
https://metraipolis.com/documento/dc_2cfc90113154

How to cite

Event-Based Estimation for Detrusor Pressure Using a Single Bladder Catheter Augmented with Abdominal Electromyography — arXiv:2609.20993 — arXiv (en), https://arxiv.org/abs/2609.20993 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_2cfc90113154 (Metraipolis archive dc_2cfc90113154, sha256 c990009029df855fd6efdbc43fd991a9ce5ff3c274c871cb2fe2829c309bfca9)
BibTeX
@misc{dc2cfc90113154,
  title = {Event-Based Estimation for Detrusor Pressure Using a Single Bladder Catheter Augmented with Abdominal Electromyography — arXiv:2609.20993},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.20993},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_2cfc90113154; sha256 c990009029df855fd6efdbc43fd991a9ce5ff3c274c871cb2fe2829c309bfca9},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.20993. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Objective: The aim of this study was to enhance patient comfort and diagnostic accuracy in urodynamic studies (UDS) by developing a novel framework that uses a single vesical pressure (Pves) channel combined with a surface abdominal electromyography (AEMG) electrode array to estimate detrusor pressure (Pdet) without the need for an abdominal catheter. The proposed method was designed to operate in real-time, and to be compatible with current UDS clinical hardware. Methods: 40 UDS studies were performed with AEMG measured simultaneously with both Pves and Pabd. A predefined, provocative abdominal maneuver was used before each study to ensure accurate coupling between the AEMG signal and associated abdominal pressures seen in Pves. Criteria were set to determine if coupling was sufficient for Pdet estimation from Pves and AEMG. Post-hoc signal processing was used to further refine and evaluate estimated Pdet using automated, non-causal event detection. An event-based scoring metric was used to determine how accurately this approach estimated Pdet by calculating the percentage of signal contained in the appropriate channel for that event (Pdet vs abdominal pressure). Results: The results showed that 30 of the 40 cases indicated a "Go" status after the provocative maneuver, demonstrating feasibility of this method in a majority of UDS studies. The scoring metric, along with correlation analysis, confirmed accuracy of estimated Pdet with scores ranging from 85% to 95% with median at 93%. Significance: This innovative approach has the potential to revolutionize urodynamic studies by providing a more comfortable and accurate diagnostic tool for assessing bladder function. This is particularly beneficial for vulnerable populations, such as the elderly and children, reducing the need for multiple catheters and improving the overall patient experience during UDS.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-21 in eess.SP).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2609.20993 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-10T03:01:19.796Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).